background image

10

Spare part overview article numbers

Nr.

Art.Nr.

Description

1

B18309

Decorative door assy

2

L03494

Hinge plate

3

L03493

Securing plate

4

N112027

Magnet

5

N112190

Hexagon socket screw

6

Z37140

Combustion chamber door black

B18311

Combustion chamber door assy

7

N103693

Flat seal black 8x2

8

Z36626

Combustion chamber door glass

9

N100476

Sealing cord black D10

10

N112426

Hexagonal screw

11

L03317

Hinge plate

12

L03318

Hinge plate

13

N109985

Allen screw

14

N112425

Grub screw

15

N112424

Hexagon socket screw

16

L03321

Flat washer

17

N112427

Headless screw

18

L03339

Hinge plate

19

L00475

Glass holder

20

N111799

Hexagonal screw

21

Z34857

Locking bolt

22

N111882

Grub screw

23

L02219

Holder plate

24

N111856

Hexagonal countersunk screw M04x12

25

L02220

Lock tongue

26

N111965

Washer M05

27

N111950

Hexagonal screw M05x10

28

L03350

Lock angle

29

N112240

Self-tapping screw M05x10

30

N112428

Headless screw

31

N112140

Hexagonal screw

32

N112095

Telescopic rail

33

LB00699

Rail angle left

34

N110032

Hexagonal screw

35

N112241

Self-locking nut

36

N112015

Flue pipe sealing

37

N112023

Seal ait intake

38

Z18278

Air intake

39

Z37844

Pipe adapter

N108313

Self-tapping screw

40

Z37830

Pipe adapter seal

41

Z36567

Sealing

42

Z35999

Cleaning cover

43

N112290

Wing nut

44

N112490

Levelling screw black

45

L03392

Plinth panel

46

N112297

Self-locking nut

47

Z37483

Detent plate

*1

Z37054

Detent plate

48

N112393

Micro switch

49

N111950

Hexagonal screw M05x10

Nr.

Art.Nr.

Description

50

N105179

Hexagonal nut M10

51

L03330

Washer

52

LB00701

Rail angle right

53

Z36778

Blind cover

56

B18188

Cover combustion chamber assy

N100476

Sealing cord black D10

57

N112423

Wing screw

58

Z36623

Baffle plate

59

Z36607

Cast rear panel, top black

60

Z36606

Cast rear panel bottom black

61

N112170

Hexagon socket screw

62

Z36622

Firebrick lining left

63

Z36624

Firebrick lining right

64

B17529

Fire trough holder

65

N103066

Round sealing strip black D06

66

N111846

Hexagon socket 06x12

67

Z35804

Recess

68

L03314

Ash drawer

69

Z37008

Seal

70

Z37009

Cleaning opening

71

N112419

Wing screw

73

N101143

Cylinder allen screw

74

L03492

Locking lever

75

N109985

Allen screw

76

L03491

Mounting plate

77

Z37441

Locking bolt

78

L03490

Mounting plate

79

N112393

Micro switch

80

L03489

Lock tongue

81

N109985

Allen screw

82

L03356

Closure flap

83

N112138

Hexagonal screw

84

N112009

Flat washer

85

N104477

Allen screw

86

N111975

Hexagonal nut M04

87

N112142

Flange nut

88

L03355

Slip sheet

89

Z37057

Strap hinge

90

L03354

Pellet chute

91

Z35906

Seal

92

B18475

Container lid

93

N111965

Washer M05

94

N112169

Hexagon socket screw

95

Z35691

Spring plug

96

N112185

Self-tapping screw M05x10

97

N112017

Key

100

N106175

Hexagonal nut

101

N112009

Flat washer

102

N112027

Magnet

103

L03316

Spacer plate

104

B18286

Cover 

Note: Please consider the powdercoated parts can differ slightly in colour and colour effects though they are elaborated in high quality�

Содержание Revivo 125

Страница 1: ...Operating manual REVIVO 140 REVIVO 125...

Страница 2: ...ording to ENplus A1 15 Pellet container refilling during operation 15 Pellet storage 15 6 TECHNOLOGY AND SAFETY FUNCTIONS 16 Operating comfort 16 Top efficiency lowest emissions 16 Pressure monitoring...

Страница 3: ...20 Cleaning the flue pipes 21 Combustion air intake 21 Cleaning the convection air openings 21 Cleaning the pellet container 21 Checking door seal 21 Bearings 21 11 PROBLEMS POSSIBLE SOLUTIONS 22 Prob...

Страница 4: ...Model Identifier Equivalent models REVIVO 125 REVIVO 140 RIKA Innovative Ofentechnik GmbH Andreas Bloderer M llerviertel 20 4563 Micheldorf Austria Test report no Applied harmonised standards Other ap...

Страница 5: ...021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innov...

Страница 6: ...0 10 19 20 17 30 23 25 24 24 26 27 16 28 29 1 6 21 22 2 2 5 3 4 4 44 44 51 50 32 32 33 52 34 34 37 38 36 49 53 53 41 42 43 41 42 43 41 42 43 36 44 35 35 45 46 31 48 47 39 40 39 40 3 TECHNICAL DATA Spa...

Страница 7: ...7 6 EN 64 65 66 60 61 59 61 67 62 63 58 68 69 70 71 56 57 75 81 87 91 90 85 89 88 85 86 85 93 94 82 84 83 79 92 77 78 76 80 74 73 95 96 97...

Страница 8: ...100 107 106 106 104 102 105 105 109 110 114 113 112 111 115 108 157 156 155 153 154 128 129 127 126 133 145 132 152 147 148 149 150 151 125 124 121 120 123 122 130 131 134 141 146 136 138 137 137 143...

Страница 9: ...9 8 EN Spare part overview exploded diagram REVIVO 125 173 160 168 172 171 170 169 166 163 165 164 161 167 174 175...

Страница 10: ...Detent plate 1 Z37054 Detent plate 48 N112393 Micro switch 49 N111950 Hexagonal screw M05x10 Nr Art Nr Description 50 N105179 Hexagonal nut M10 51 L03330 Washer 52 LB00701 Rail angle right 53 Z36778 B...

Страница 11: ...nting bracket 139 N112402 Rocker switch 140 N111604 Fuse 2 5 A 141 L03409 Support for drag chain 142 N112394 Chain 143 N112102 Differential pressure switch 144 N103990 Allen screw M04 x08 145 N111581...

Страница 12: ...ature C 148 Chimney draft requirement Pa 3 The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing system...

Страница 13: ...on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your stove is burning the use of highly inflammable and explosive materials in...

Страница 14: ...ustion chamber door is to be kept closed when the stove is not in operation Q Foulingofthechimneyi e depositsofhighlyinflammablematerials such as soot and tar and subsequently fire in the chimney may...

Страница 15: ...conducting measurements with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a l...

Страница 16: ...acknowledging the error message at the internal unit Note Maintenance and cleaning work must be performed if overheating occurs If this error recurs operation without danger is no longer guaranteed n...

Страница 17: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 18: ...the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives an ext...

Страница 19: ...ing cloth or newspaper Cleaning of the burn pot daily Make sure that the air vents are not blocked with ash or clinker Remove the clinker using the supplied brush and vacuum the burn pot The burn pot...

Страница 20: ...Resets menu Note Yourstovemustbeswitchedoffandcooledbeforeanymaintenance work is performed Only work on the unit when the mains plug has been disconnected Cleaning the flue gas channels Disconnect yo...

Страница 21: ...ush off any soot and dust deposits in the fire and in the flue pipes and vacuum Note Accumulated fly ash in the flue gas channels may impair the performance of the stove and pose a safety risk Combust...

Страница 22: ...G MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in...

Страница 23: ...ions These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important po...

Страница 24: ...eight Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YE...

Страница 25: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Страница 26: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Страница 27: ...27 26 EN...

Страница 28: ...only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z37505_REVIVO_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH M llervie...

Отзывы: