![Rigol RSA5000 Series Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/rigol/rsa5000-series/rsa5000-series_user-manual_1461066034.webp)
RIGOL
Chapter 1 Quick Start
1-20
RSA5000 User’s Guide
frequency and stop frequency.
24
Y scale
I ndicates the scale indication in the Y axis.
Note
[ 1]
:
The display of the trace indicator is shown in the following f igure:
The f irst line displays the trace number. The color of the number is the same as that of
the trace.
The second line displays the trace type, including W (Clear/ Write), A (Trace Average), M
(Maximum Hold), and m (Minimum Hold). The letters with different colors and in
different forms show different meanings.
—
The letter in blue indicates that the trace is updating.
—
The letter in gray indicates that the trace is not updated.
—
The letter with strikethrough and in gray color indicates that the trace will neither
be updated nor displayed.
—
The letter with strikethrough and in blue color indicates that the trace is updating
but not displayed. I t is useful in trace math operation.
The third line displays the detector type of each trace, including N (Normal, only available for
GPSA), V (Voltage Average, only available for GPSA), P (Positive Peak), p (Negative Peak), S
(Sample), R (RMS Average, only available for GPSA), Q (Quasi Peak, only available for GPSA),
and A (Average, only available for RTSA). I f it shows "f ", it indicates that it is math operation
trace. The letter in blue in the third line (detector type) indicates that the detector is in auto
state; the letter in white indicates that it is in manual state.
Mouse/ Keyboard/ Touch Screen Operation Rule
Mouse Operation Rule
Connect the mouse (note that only the left-click operation is supported; the scroll
and right-click operations with the mouse are not supported) to the spectrum
analyzer via the USB HOST interface to perform the following operations:
1.
Click to select the menu and window.
2.
Press and hold the left mouse button to drag the data displayed on the graticule
or move the slide bar.
3.
Double-click the data displayed on the graticule and then the data will be
appeared at the right-corner.
4.
Under the Marker function, you can only use the mouse to move a marker, but
unable to add a marker with the mouse.
Trace Number
Trace Type
Detector Type