![Rigol RSA5000 Series Скачать руководство пользователя страница 138](http://html.mh-extra.com/html/rigol/rsa5000-series/rsa5000-series_user-manual_1461066138.webp)
RIGOL
Chapter 3 Functions of the Front Panel of RTSA
3-10
RSA5000 User’s Guide
Trigger
Press
Trigger
on the front panel to enter the trigger setting menu. The settings for
the trigger parameters are basically the same as that in GPSA. I n RTSA, I F power
trigger and FMT are added. The Video trigger is not supported.
The following section will introduce I F power trigger and FMT. For descriptions about
the parameter settings for "Slope", "Trigger Delay Switch", "Trig Delay", "Trigger
Holdoff Switch", "Trigger Holdoff ", "Auto Trig Switch", and "Auto Trig", please refer to
"
Trigger
" in Chapter 2.
Acq/ Trigger
Sets the number of times for acquisition after each trigger signal that meets the
requirements generated a trigger.
Table 3-8 Acq/ Trigger
Parameter
Remarks
Default
1
Range
1 to 8,192
Knob Step
1
Left/ Right Arrow Key Step
Up/ Dow n Arrow Key Step
at 1-1.5-2-3-5-7.5 step
Pow er Trigger
A trigger signal will be generated when the system detects that the I F signal power
exceeds the set I F power.
Pow er
Sets the trigger level of the I F power trigger. When the signal meets the set trigger
edge and exceeds the trigger level value, a trigger occurs. The I F power level is
displayed in the waveform display area in the form of horizontal lines. When the set
value is not within the waveform display range, the trigger level line is displayed at
the top or bottom of the waveform display area.
www.valuetronics.com
Содержание RSA5000 Series
Страница 2: ...www valuetronics com ...
Страница 14: ...www valuetronics com ...
Страница 162: ...www valuetronics com ...
Страница 172: ...www valuetronics com ...
Страница 192: ...www valuetronics com ...
Страница 198: ...www valuetronics com ...