CALIBRATION
& UNIT OF MEASURE
17
RE-CALIBRATION
It is required to re-calibrate every 6 months for each axle group being
measured. For more information on TCA requirements, refer to pages 7-8.
TCA OBM Requirement:
LOADED CALIBRATION POINT
Repeat “empty calibration point” steps 1-3 with the vehicle
fully loaded.
4: Press the ON/OFF button to turn on the Right Weigh
load scale.
5: Press the blue MENU button to select the proper axle
group or calibration set.
6: Press and hold the C HIGH button until the “C/H” symbol
appears.
7: Adjust the value using the UP and DOWN arrows so that
it matches your scale ticket for the axle group.
8: To save, press and hold the C HIGH button until the
“C/H” symbol disappears.
9: Repeat steps 5-8 for all axle groups or calibration sets.