Rigel wifi-nSTEP Скачать руководство пользователя страница 11

wifi-nSTEP Instructions 

 

Copyright Rigel Systems 2010 

Page 11 of 12 

www.rigelsys.com 

 

 

 

From TOP LEVEL DISPLAY press 

Menu

 

FOUR times to enter 

 

TEMP SETUP 

 

 

 

 
 

While in TEMP SETUP press 

S-Menu

 ONCE 

for 

 

DeltaTemp 

 

T

his is the temperature change x10 to trigger a  

compensation.  

Use F+/F- keys to change the Delta Temp 

value   

 

 

 

 

 

While in TEMP SETUP press 

S-Menu

 TWICE 

for 

 

TempMove 

 

Move this many steps for each Delta Temp 

change.  Direction of movement controlled by 

sign of DeltaTemp.  

Use F+/F- keys to change the TempMove value   

Range is 0 to 75 

 

 

 

 
 

While in TEMP SETUP press 

S-Menu

 THRICE 

for 

 

TempBklash 

 

Apply this number of steps in last move direction 

before reversing direction.  

Use F+/F- keys to change the Delta 

Temperature value  

Usually not needed for Crayford focusers 

 

 

 

 

 

While in TEMP SETUP press 

S-Menu

 FOUR 

times for 

 

Temperature Compensation 

Mode 

 

Use F+/F- keys to change the internal temperature 

compensation mode between 

Of

 (off), 

Ma

 (Manual), 

Au S

 (Auto). Au(to) mode - must stay on this screen 

while auto temp compensating, leaving the screen 

turns off Au(to). Watch the position display or the 'S' or 

'M' next to the Au to see movement. Entering MA or 

Au mode, the current temperature is used as the 

baseline. if in Au(to) mode, changing from this temp 

will force an Au(to) move.  

 

 

 

While in TEMP SETUP press 

S-Menu

 FIVE 

times for 

 

DoTempComp 

 

If Temperature Compensation Mode is 

Ma

 

(Manual) then press F+ to set the “

Prime for 

Manual

” compensation using the current 

temperature and position as the starting point. 

If Temperature Compensation Mode is 

Of

 (off) or 

Au S

 (Aut) displays 

Frce Comp Disabld

.  Do 

Temp Comp= S. Pressing either F+ or F- will 
take the base temperature versus currently 
display temp and move Delta steps base on 
Temp delta. 

 

 

 

 

Содержание wifi-nSTEP

Страница 1: ...8 1 Press Win C on your keyboard to open the Windows Charm bar Select the gear icon in the charm bar Selecting this icon will bring you to the modern ui control panel WINDOWS 8 Select General scroll a...

Страница 2: ...3 Windows 10 now has usb drivers To see which COM port the wifi nSTEP is on use the windows device driver and look for a new usb device COM port assignments can be changed to match in the SETUP window...

Страница 3: ...Ready to go Use the shortcut on your desktop to activate the Wifi nSTEP application 1 Year limited warranty Rigel Systems 26850 Basswood Ave Rancho Palos Verdes CA 90275 warrants to the original consu...

Страница 4: ...ition Description Lets the user label the position for ease of operation Internal Temp Comp This function runs the temperature internally to the nSTEP so a user can actually configure it and then exit...

Страница 5: ...Turn coils off after stepping to save power and reduce heating of the stepper motor Only use with a gear head stepper a non gearhead stepper may slip lifting heavy loads Phase Select set in factory to...

Страница 6: ...Android Menu go to phone settings Accessibility Dexterity and Interaction Assistant menu At the top right slide the off button to On Now on all screens is a little round button with 4 dots on it if y...

Страница 7: ...eft to go slower right to go fast will only go as fast as Max Speed allows see below under Motor Setup NOTE There is a deadman timer of 10 seconds on F and F presses so if wifi connection is lost step...

Страница 8: ...YS ON Press F F to toggle backlight always on While in DISPLAY SETUP press S Menu THRICE times for BACKLIGHT ON TIME If Backlight Always On 1 display will confirm otherwise If Backlight Always On 0 No...

Страница 9: ...5 stored positions to Goto then press F to force GoTo the position shown From TOP LEVEL DISPLAY press Menu THRICE for SAVE POSITION Press S Menu multiple times to select slot 0 through 4 then press F...

Страница 10: ...H Half F Full While in MOTOR ADVANCED press S Menu TWICE to SET COILS ON OFF Use F F keys to change the Coils On Off This is indicated by 0 On or 1 Off to the right of the stepping type to right of H...

Страница 11: ...sers While in TEMP SETUP press S Menu FOUR times for Temperature Compensation Mode Use F F keys to change the internal temperature compensation mode between Of off Ma Manual Au S Auto Au to mode must...

Страница 12: ...wifi nSTEP Instructions Copyright Rigel Systems 2010 Page 12 of 12 www rigelsys com...