A. RS485 port can be used as either expansion or communication port, while serving as
communication port, EXM-E-RS485 communication module would be required as such port is not photo
electricity-isolated.
3.3 Resources
3.3.1 GSM /GPRS
module
built- in
Each x-Messenger CPU integrates an industry Quad-band GSM module inside. The x-Messenger can work
under the following GSM networks: 850MHz, 900MHz, 1800MHz, 1900MHz and will search these frequency
bands automatically.
Note: A. all the x-Messenger CPUs support the GSM function except the EXM-12DC-DA-RT-WIFI.
Model
EXM-12DC-DA-RT-WIFI
EXM-12DC-DA-RT-GWIFI
Supply Voltage
DC 12-24V
DC 12-24V
Inputs
4 digital/4 digital
Analog Input signal
4 DC (0..10V)
Outputs
High Speed Count(I7,I8)
2 relay(10A)
+2 Transistor(0.3A)
(I7,I8)60kHz
SMS
No
Yes (64 different short message configuration)
GPRS
No
Yes
Wifi interface
Yes
Yes
Ethernet
Yes
Yes
Data logging
Optional(Optional accessory: ELC-MEMORY required)
Interface
1 RS232 & 1 RS485
Communication protocol
Modbus RTU&ASCII/TCP
Modbus RTU /ASCII /TCP
RTC
Yes
LCD display with keypad
Yes
Alarming mode
No
SMS, Ring
output control mode
Logic program control
SMS , Call-In, Logic program control
Programming
Standard config soft& Customized soft(Function block diagram)
No
Yes(can send email out)
Содержание EXM-12DC-DA-R-HMI
Страница 15: ...15 Application 2 Home Security Application 3 Remote monitoring of product level in a tank...
Страница 32: ...32 Note This command is only for 2G version unit it is unavailable for 4G version unit MsgI01 MsgI02...
Страница 35: ...35 How to change the phone book include phone number and Email address Only for 4G version...
Страница 38: ...38...
Страница 49: ...49 Step C Download voice section Click menu Tool Record Click Hardware Detect button...
Страница 66: ...66 You can read the parameters from the PLC...
Страница 68: ...68...
Страница 75: ...75 Modbus Poll works as TCP client...
Страница 78: ...78 TCP Sever 192 168 0 227 port 8004 is ok TCP Sever 192 168 0 227 port 8005 is ok...
Страница 79: ...79 TCP Sever 192 168 0 227 port 8006 is ok TCP Sever 192 168 0 227 port 8007 is ok...
Страница 80: ...80 TCP Sever 192 168 0 227 port 8008 is ok TCP Sever 192 168 0 227 port 8009 is ok...
Страница 84: ...84 3 Click Read button to read web server configure The default configuration is as follows...
Страница 102: ...102 Slave1 IP 192 168 0 101 TCP server port 8001 Slave2 IP 192 168 0 102 TCP server port 8002...
Страница 103: ...103 Slave3 IP 192 168 0 103 TCP server port 8003 Step 2 Program in master and slave...
Страница 115: ...115 Slave1 IP 192 168 0 101 UDP Server port 8001 Slave2 IP 192 168 0 102 UDP Server port 8002...
Страница 116: ...116 Slave3 IP 192 168 0 103 UDP Server port 8003 Step 2 Program in master and slave Master program...
Страница 128: ...128 Network settings You can view the network parameters in such table...
Страница 135: ...135 3 Select Ethernet option 4 To search PLC s IP by clicking Search button...
Страница 143: ...143 B001 Transfer the I1 I4 status from the master to the Q1 Q4 of the slave1 Setting as follows...
Страница 144: ...144 B002 Transfer the I1 IA status from the master to the Q1 QA of the slave2 Setting as follows...
Страница 145: ...145 B005 Read the I1 I4 status from the slave1 to the F11 F14 of the master Setting as follows...
Страница 146: ...146 B006 Read the I1 IA status from the slave2 to the F21 F24 of the master Setting as follows...
Страница 147: ...147 B009 Read the AF1 value from the slave1 to the AF1 of the master Setting as follows...
Страница 148: ...148 B010 Read the AF1 value from the slave2 to the AF2 of the master Setting as follows...
Страница 156: ...156 Manual programming menu How to program via keypad Please refer to the chapter 5 for more detail...
Страница 259: ...259 C Analog input value of ELC 12 CPU and extensions D Analog output value of CPU and extensions...
Страница 260: ...260 E F digital flag status F AF analog flag value...
Страница 261: ...261 G M status H AM value...
Страница 263: ...263 C Press ok for 3 seconds and enter into edit mode D Modify value by pressing arrow keys and confirm with OK key...
Страница 332: ...332 For example If the Memory Read block had been triggered the Q1 of ELC 12 CPU will be set 1...
Страница 359: ...359 6 5 52 Comparison of 2 values Short Description The COMPARE function is used to compare two analog values...
Страница 395: ...395 Right click Q2 and then click Set Output State Click OK button and the Q2 of x Messenger will be turned off...
Страница 398: ...398 4 Click to transfer data into one excel file it contains AI1 AQ number value and the corresponding time...
Страница 411: ...411 Establish the communication between eSmsConfig and EXM WIFI Unit...
Страница 412: ...412 Two communication modes available A EXM WIFI unit works as server eSmsConfig works as client...
Страница 413: ...413 B EXM WIFI unit works as client eSmsConfig works as server eSmsConfig com settings Web page settings of wifi module...
Страница 422: ...422 The default settings of HF A11 is closed if you want to use the LAN port please select open AP setting item STA item...
Страница 426: ...426 7 6 How to configure WIFI connection TCP protocol among EXM WIFI CPUs...
Страница 430: ...430 B001 Transfer the I1 I4 status from the master to the Q1 Q4 of the slave1 Setting as follows...
Страница 431: ...431 B002 Transfer the I1 IA status from the master to the Q1 QA of the slave2 Setting as follows...
Страница 432: ...432 B005 Read the I1 I4 status from the slave1 to the F11 F13 of the master Setting as follows...
Страница 433: ...433 B006 Read the I1 I4 status from the slave2 to the F21 F23 of the master Setting as follows...
Страница 434: ...434 B009 Read the AF1 value from the slave1 to the AF1 of the master Setting as follows...
Страница 435: ...435 B010 Read the AF1 value from the slave2 to the AF2 of the master Setting as follows...
Страница 436: ...436...