Passive infrared detector «Foton-21» (hereinafter, the Detector) is intended 

for detecting intrusion into a closed protected space and generating an alarm 
message by relay output contacts opening.

The Detector ensures tamper protection by means of «Tamper» microswitch 

relay contacts opening.

The Detector is resistant to the ambient light impact and radio interference.
The Detector ensures absence of false alarms cased by movement of  small 

animals: mice, rats, birds in cages at a distance to them not less than 2.5 m.

The Detector is distinct in: attractive design, ease of installation and 

maintenance. 

2 Features

- The Detector is designed for ceiling mounting.
- Sensing elements – two dual-element pyrodetectors.
- Digital temperature compensation.
- Unique lens provides wide-range detection zone with high filled density, 

ensuring reliable detection of the intrusion in any direction.

- Protection against intrusion of insects to a pyrodetector.
- Microprocessor-based signal processing.
- Choosing of installation height as well as the following modes: testing, alarm 

memory, and LED indication.

- Self-test mode ensuranse.
- The Detector is supplied from DС current supply unit with output voltage 

(9 … 15) V.

3 Specifications

Table 1

Parameter

Value

Detection zone diameter at mounting height:

5 m, not less than

2.5 m, not less than

9 m

4.5 m

Power supply

9...15 V DC,  current 17 mА

Output relay contacts

Energized Form A (NC) relay, max.

current 30 mА, voltage 72 V

Alarm message duration, not less than

2 sec

Detection zone

Wide-angle, cone-shaped.

Zones: 10 long-range, 1 middle-range, 

1 short-range

Detection range at the installation height  

5 m and 2.5 m

Is chosen by «1» DIP-switch

Operating temperature

minus 40  ...  +50 °С

Relative humidity at 25 °С without moisture 

condensation

95 % 

IP Rating

IP41

Dimensions (diameter х height), not more than

105 х 45 mm

Weight, not more than

100 g

Detection zone pattern is shown in Figure 1.

PASSIVE INFRARED 

DETECTOR

«FOTON-21»

Installation Guide

When choosing the Detector installation place, it is advisable to take note 

of the fact that the detection zone may be limited by non-transparent objects 
(curtains, houseplants, cabinets, bookcases, etc.), as well as by glass and mesh 
partitions. There must be no windows, air conditioners, space heaters or heating 
radiators in the PIR-detection zone.

The Detector wires should be laid far enough from power supply cables.

7 Installation of the Detector

- Put off the Detector cover by it’s turning counter-clockwise until tight to the 

recess on the external ring of the Detector base and then rise the cover (Figure 2).

Figure 2 – Base and cover of the Detector

- Put off the printed circuit board (PCB) by unfastening the latch, located 

on the base.

- Drill the holes in the base (See Figure 3) for the Detector wiring and 

fastening the base.

- Choose the place of installation, mark the places for mounting holes with 

regard to the openings on the Detector base, drill holes in the place of installation.

- Insert wires into the hole in the base leaving several centimeters for fixation 

inside the case and connection to the leading-in sockets.

- Fix the base of the detector on the chosen place.
- Set down PCB on their places.

8 Connection

- Leading-in sockets for the Detector connection are located on the PCB.
- Fulfill connections in accordance with Figure 3а (for hooking up to single 

AL) or Figure 3b (to single tamper control AL).

- Set up the DIP-switches «1», «2», «3», «4»  in accordance with particular 

application conditions and Cl.9 of herein Installation Guide.

- Install the Detector cover on it’s place. For this purpose insert the bulge 

to the recess on the base external ring, push the cover and turn it in clockwise 

Bulge

Base

Cover

Recess

Openable holes for the 

base fastening

Port plugs for wiring

Latch

Figure 1 – Detection zone pattern

Ambient class: Boreal Climate (background temperature 15 – 35 

о

С, relative 

humidity 25 – 75 %, air-pressure 86 – 106 kPa), permissible relative humidity 
at +25 °С without moisture  condensation.

4 Scope of Delivery

Each Detector unit package contains the items listed in Table 2.
Table 2

Name

QNT.

Passive infrared detector «Foton-21» 
Passive infrared detector «Foton-21». Installation Guide

1 pc.

1 copy

5 Field of Application

The Detector can be applied in flats, shops, offices, museums, industrial 

facilities.

6 Choosing the Installation Place

The Detector is designed for operation in heated closed premises.

Figure 3

9 DIP-switches Positions

Table 2

Mode

DIP-switch

DIP-switch position

ON

OFF

Installation height

«1»

«5 m»

«2.5 m»

Detection zone 

testing (sizing) 

«2»

«ZONE»

Testing

«ALARM» 

Normal operation

Alarm indication

«3»

«IND» 

is ON

«OFF»

is OFF

Alarm memory

«4»

«MEM»

is ON

«OFF»

is disabled

10 LED Indication

Two-color LEDs on the front cover are used for the Detector state displaying.
Table 3

Message

LED Color

LED State

«Warm-up time»

red

Blinking at a frequency 1 Hz during 55 sec after 

energizing

«Norm»

-

Indication is OFF

«Alarm»

red

Indication is ON during 3 sec

«Failure»

green

Single three-shot  switching with a period of  

3 sec in accordance with Cl. 15

«Alarm Memory»

green

LED indication is ON in 5 min.after «Alarm» 

message for 15 min

Detection zone 

positioning

red

Switching for 0.25 sec under crossing of each 

ray of the DZ. Mode duration is 5 min after 

warm-up time

Circuit

Cont.

1
2
3
4
5
6

+12V

-12V

AL
AL

Taper
Taper

To power 
source

R

term1

To CP

а)

Taper-
control 
AL

Security 
AL

R

term1

Circuit

Cont.

To power 
supply unit

R

term1

Detector

1
2
3
4
5
6

+12V

-12V

AL
AL

Taper
Taper

b)

Detector

10 m

5 m

9 m

Отзывы: