20017376
6
GB
Technical description of the burner
4.1
Models available
4.2
Technical data
4.3
Country of destination - Gas category
4
Technical description of the burner
Designation
Electrical supply
Code
RX80 S/PV
1/220-230V/50-60Hz
20015486
RX100 S/PV
1/220-230V/50-60Hz
20015837
RX120 S/PV
1/220-230V/50-60Hz
20015840
Model
RX80 S/PV
RX100 S/PV
RX120 S/PV
Thermal power
kW
Kcal/h
22 ÷ 76
18.900 ÷ 65.360
31 ÷ 99
26.660 ÷ 85.140
37 ÷ 122
31.820 ÷ 104.920
Natural gas -
(Family 2)
G20
Net calorific value: 9.45 kWh/Sm
3
= 8,100 kcal/Sm
3
- Pressure 10 - 30 mbar
G25
Net calorific value: 8.125 kWh/Sm
3
= 7,000 kcal/Sm
3
- Pressure 10 - 30 mbar
LPG -
(Family 3)
G30
Net calorific value: 32.247 kWh/Sm
3
= 27,730 kcal/Sm
3
- Pressure 10 - 30 mbar
G31
Net calorific value: 24.44 kWh/Sm
3
= 21,000 kcal/Sm
3
- Pressure 10 - 30 mbar
Electrical supply
Single-phase, ~ 50/60Hz 220/230V ± 10%
Fan
Max. 6000 rpm - 50/60Hz
Ignition transformer
Primary 220V - 240 - 50 - 60H
z
– Secondary 15 kV - 25 mA
(1) Reference conditions:
Air temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
Country
IT - GB - AT - DK - IE - ES - GR - PT
NO - SE - FI - CZ - CH - EE - LT
LV - PL - LU
DE
FR
BE
NL
Gas categories
I
2H
I
2E
I
2ELL
I
2Er
I
2E(R)B
I
2L
Pressure
(mbar)
G20
20
20
20
20/25
20/25
-
G25
25
25
25
25
25
25
Country
IT - GB - AT - IE - ES - GR - PT
CZ - CH - DE - FR - BE
AT - CH - DE - DK
FI - NL - NO - SE
Gas categories
I
3P
I
3B/P
Pressure
(mbar)
G30
-
29
G31
29
-