SYSTEM MANAGER
12
The burner should now ignite and remain in operation
until the set temperature is reached.
The burner will then switch off and on automatically to
maintain the set temperature without further operator
action.
If any ignition faults or malfunctions occur, the burner
performs a “LOCKOUT SHUTDOWN”. This is shown by
the red button light on the burner and by the warning light
on the control panel.
b
If a “LOCKOUT SHUTDOWN” occurs, wait about 30
seconds before resetting the burner.
To reset the burner, press the red button light on the
burner and wait until the flame ignites.
Repeat this operation 2 -3 times at the most. If the prob-
lem persists after that, call
r
’s Technical Assistance
Service.
If you need to shut down the system for a short period,
proceed as follows.
- Turn the control panel power switch OFF and make
sure that the green power indicator goes out
- Turn the mains power switch OFF
b
Do NOT perform this procedure if outdoor tempera-
ture falls below ZERO (risk of freezing).
Then proceed as follows:
- Adjust the boiler thermostat to its minimum setting
(60°C)
- Make sure that the temperature controller or timer /
room thermostat is set to “frost protection” mode.
TEMPORARY SHUTDOWN
20
40
60
80
100
0
120
20
40
60
80
100
0
120