20068131
36
GB
Start-up, calibration and operation of the burner
6.6.3
Service mode
The
Service mode
(
SEr
) visualises the error log and certain
technical information about the system. To access this level you
must:
press the
“i/reset”
key for more than 3 s.
Release the key immediately when the display shows
“SEr”
.
The list of parameters (in the sequence in which they are dis-
played) is shown in Tab. M.
Tab. M
6.6.3.1 Operating mode on Info Mode and Service Mode
After access to these levels, the display visualises the number of
the parameter (flashing) on the left, and the corresponding value
on the right.
If the value is not displayed, press the
“i/reset”
key for a period
of 1 - 3s.
To return to the Parameter List, press the
“i/reset”
key for more
than 3s, or press the keys
“+”
and
“-”
(
ESC
) simultaneously.
To move on to the next parameter, press the
“+”
or
“i/reset”
key
for less than 1 s. At the end of the list, the display visualises
“End”
.
To move back to the previous parameter, press the key
“-”
.
To return to the Normal/Standard visualisation mode, press the
“i/
reset”
key for more than 3s, or press the keys
“+”
and
“-”
(
ESC
)
simultaneously.
For a moment the display will show
“OPErAte”
.
6.6.4
Parameter mode
The
Parameters Mode
(
PArA
) displays, and allows to be mod-
ified/programmed, the list of parameters indicated on page 44.
The factory-set parameters are not visible.
To access this level you must follow
.
6.6.4.1 Access procedure with password
Press the
“F”
and
“A”
keys simultaneously for 1s.
For a moment the display will show
“CodE“
, and immediately af-
ter you will see 7 dashes, the first one flashing.
With the keys
“+”
and
“–”
select the first character of the pass-
word (letter or number), and confirm by pressing the key
“i/re-
set”
.
Once you have confirmed, the sign
“–”
will appear.
Continue in the same way for the other characters.
After inserting the last character of the password, confirm by
pressing the key
“i/reset”
: if the password inserted is correct you
will see
“PArA“
for a few seconds, then you can access the var-
ious groups of parameters.
With the keys “
+”
and “
–”
select the group you require.
If the password inserted is incorrect, the message
“Error“
will
appear for a moment. It is then necessary to repeat the proce-
dure.
No.
Parameter
954
Flame intensity (%)
960
Actual fuel which passes in units of volume / h
(m³/h, l/h, ft³/h, gal/h)
121
Manual setting of output
Not defined = automatic operation
922
Position of the servomotors (expressed in de-
grees, symbol )
0 = fuel
1 = air
161
Number of errors
701÷725
Log of the errors: 701-725.01, Code
/reset
D9020
P
s
h
V
min
%
D9021
P
%
min
h
s
D9025
P
V
%
min
h
s
D9026
P
V
%
s
min
h
VSD
A
F
/reset
D9027
P
h min s
%
V
/reset
D9022
P
s
h min
%
V
D9023
P
V
%
s
min
h
D9024
P
h min s
%
V
Содержание RS 34/E MZ
Страница 2: ...Translation of the original instructions ...
Страница 65: ...63 20068131 GB Appendix Electrical panel layout RS 34 E MZ ...
Страница 66: ...20068131 64 GB Appendix Electrical panel layout RS 44 E MZ ...
Страница 67: ...65 20068131 GB Appendix Electrical panel layout RS 44 E MZ 3Ph ...
Страница 68: ...20068131 66 GB Appendix Electrical panel layout RS 34 44 E MZ ...
Страница 69: ...67 20068131 GB Appendix Electrical panel layout RS 44 E MZ 3Ph ...
Страница 70: ...20068131 68 GB Appendix Electrical panel layout ...
Страница 71: ...69 20068131 GB Appendix Electrical panel layout ...
Страница 72: ...20068131 70 GB Appendix Electrical panel layout ...
Страница 73: ...71 20068131 GB Appendix Electrical panel layout ...
Страница 75: ......