ELECTRICAL CONNECTIONS
It is advisable to leave the control box off the sub-base while com-
pleting the electrical connection to the burner.
1) Wire access hole (Use BX electrical connector)
2) Earth ground conductor terminal (Green wire)
3) Hot conductor terminal (Black wire)
4) Neutral conductor terminal (White wire)
5) Strain relief clamp
Using the appropriate diagram below, make electrical connections
to burner. All wiring must be done in accordance with existing elec-
trical codes, both national and local.
When all electrical connections have been made, the control box may be put back in place on the sub-base.
APPLICATION FIELD WIRING
WARNING:
The hot (black) wire must be connected to the L terminal and the
neutral (white) wire must be connected to the N terminal or the
primary safety control will be damaged.
Do not connect wither wire to the terminal marked
.
WARNING:
DO NOT activate burner until proper oil line connections have been made, or failure of the pump shaft
seal may occur.
D7454
.
Green
NEUTRAL (White)
HOT LINE (Black)
Blue
White
Black
Brown
White
Blue
Brown
Black
CAPACITOR
MOTOR
2
3
4
5
6
7
8
9
1
N
L
120V
AC
LINE SAFETY
SWITCH
OPERATING
LIMIT SWITCH
SAFETY
LIMIT SWITCH
FUSE 15A
20101913
Black
White
EARTH
GROUND
SOLENOID
VALVE
M
~
DIRECT LINE
VOLTAGE
FACTORY WIRED
SUB-BASE