Output - Thermal power

2.3 – 5 kg/h

27 – 60 kW

Fuel

Light oil, viscosity  4 –

6 mm

2

/s at  20 °C

Electrical supply

Single phase 230 V 

±

 10% 

~

 50Hz

Motor

Run current  0.75 A

2750 rpm

289 rad/s

Capacitor 4 

F

Ignition transformer

Secondary 8 kV

16 mA

Pump

Pressure: 8 – 15 bar

min. output  22 kg/h

Absorbed electrical power

0.17 kW

1

 –  Flange with insulating gasket

2

 –  Air damper

3

 –  Photoresistance

4

 –  Nozzle holder assembly

5

 –  Reset button with lock-out lamp

6

 –  Control box

7

 –  Oil pump

8

 –  Protection crankcase

BURNER EQUIPMENT

No. 1 - Flange with insulating gasket
No. 2 - Flexible pipes with nipples

O

Burner with CE marking in conformity with EEC directives: EMC 2014/30/UE, Low Voltage 2014/35/UE, 
Machines 2006/42/EC and Efficiency 92/42/EC.

O

The burner meets protection level of  IP X0D (IP 40), EN 60529.

O

CE Certification No.: 

0036 0342/03

 as 92/42/EC.

TECHNICAL DATA

7

8

D5263

Fig. 1

ø 

89

1

21.5

80

FIRING RATE (as EN 267)

2

2.5

3

3.5

4

5

25

50

30

40

60

0.8

0.6

0.4

0.2

0

Light oil output - kg/h

Thermal power - kW

Pres

su

re in

 com

b

u

s

tio

n

D5264

ch

amb

e

r - 

m

b

ar

4.5

55

45

35

BOILER FIXING

Remove 4 screws 

(1)

, insert the

flange 

(2)

 and tighten screws 

(1)

again.  Insert the insulating gasket

(3)

 

(if necessary increase the holes

as shown in fig. 2)

 and fix the burner

to the boiler, (see fig. 3).

S7029

Fig. 2

Fig. 3

Содержание REG 35.5

Страница 1: ...Installation use and maintenance instructions 2902416 5 05 2016 Light oil burner CODE MODEL TYPE 3772216 REG 35 5 722T GB ...

Страница 2: ......

Страница 3: ...UIPMENT No 1 Flange with insulating gasket No 2 Flexible pipes with nipples O Burner with CE marking in conformity with EEC directives EMC 2014 30 UE Low Voltage 2014 35 UE Machines 2006 42 EC and Efficiency 92 42 EC O The burner meets protection level of IP X0D IP 40 EN 60529 O CE Certification No 0036 0342 03 as 92 42 EC TECHNICAL DATA 7 8 D5263 Fig 1 ø 89 121 5 80 FIRING RATE as EN 267 2 2 5 3 ...

Страница 4: ...of the valve It is necessary to install a filter on the fuel supply line H difference of level L max lenght of the suction line I D internal diameter max 4 m Fig 5 H H meters L meters I D 8 mm I D 10 mm 0 5 1 1 5 2 10 20 40 60 20 40 80 100 O Before starting the burner make sure that the return pipe line is not clogged An excessive back pressure would cause the damage of the pump seal O The pump is...

Страница 5: ...stat Remote lock out signal 230V 0 5A max Remove the protection crankcase 8 fig 1 page 1 after removing the 3 retainer screws Widen the upper slit and remove the protection crankcase inserting the oil pipe and the flexible oil lines Insert PG 13 5 cable gland 1 into the wire access hole and tighten it with the nut Insert the electrical cable into the con nector and make electrical connec tions as ...

Страница 6: ...11 2 3 0 5 2 5 0 65 60 12 2 6 1 3 5 0 75 60 12 3 0 1 5 3 5 0 85 60 12 3 4 2 5 5 0 1 00 60 12 4 0 3 7 5 1 10 60 12 4 4 4 9 0 1 25 60 12 5 0 4 10 0 COMBUSTION ADJUSTMENT Remove the nozzle holder assembly from the burner see page 3 Remove the diffuser disc assembly 1 from the nozzle holder 2 after loosening the screw 3 Insert the proper nozzle 6 into the nozzle holder and tighten securely REPLACE THE...

Страница 7: ......

Страница 8: ...Subject to modifications RIELLO S p A I 37045 Legnago VR Tel 39 0442 630111 http www riello it http www riello com ...

Отзывы: