![Riello REG 35.5 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/riello/reg-35-5/reg-35-5_installation-use-and-maintenance-instructions_1459673006.webp)
2416
4
In conformity with Efficiency Directive 92/42/EEC the application of the burner on the boiler, adjustment and
testing must be carried out observing the instruction manual of the boiler, including verification of the CO and
CO
2
concentration in the flue gases, their temperatures and the average temperature of the water in the boiler.
To suit the required appliance output, choose the proper nozzle and adjust the pump pressure, the setting of
the combustion head, and the air damper opening in accordance with the following schedule.
The values shown in the table are measured on a CEN boiler (as per EN 267). They refer to 12.5% CO
2
at sea
level and with light oil and room temperature of 20°C.
PUMP PRESSURE
: 12 bar, the pump leaves the factory set at this value.
RECOMMENDED NOZZLES
: Delavan type W -B; Danfoss type S - B; Monarch type R; Steinen type S - Q.
Nozzle
GPH Angle
Pump pressure
bar
Burner output
kg/h
±
4%
Comb. head adjustment
Set-point
Air damper adjustment
Set-point
0.60
80°
11
2.3
0.5
2.5
0.65
60°
12
2.6
1
3.5
0.75
60°
12
3.0
1.5
3.5
0.85
60°
12
3.4
2.5
5.0
1.00
60°
12
4.0
3
7.5
1.10
60°
12
4.4
4
9.0
1.25
60°
12
5.0
4
10.0
COMBUSTION ADJUSTMENT
– Remove the nozzle holder assembly from the
burner (see page 3).
– Remove the diffuser-disc assembly
(1)
from the
nozzle holder
(2)
after loosening the screw
(3)
.
– Insert the proper nozzle
(6)
into the nozzle holder
and tighten securely.
– REPLACE THE DIFFUSER-DISC ASSEMBLY (1)
AND INSERT IT IN THE NOZZLE HOLDER (2)
UNTIL THE END. LOCK WITH SCREW (3).
– Remove the nozzle holder assembly (see page 3).
– Loosen the screw
(4)
, move the electrodes assem-
bly
(5)
and lock the screw
(4)
.
It depends on the output of the burner and is carried
out by rotating clockwise or counterclockwise the set-
ting screw
(1)
until the set-point marked on the regu-
lating rod
(2)
is level with the outside plane of the
nozzle holder assembly
(3)
.
Loosen the screw
(1)
and move the indicator towards
the required set-point and then lock the screw
(1)
.
NOZZLE POSITIONING
(Fig. 10)
ELECTRODE SETTING
(Fig. 10)
COMBUSTION HEAD SETTING
(Fig. 11)
Fig. 11
S7032
1
2
3
MEASURES MUST BE
RESPECTED
WARNING:
Fig. 10
D5268
4.5
– 0.5 mm
0
2 – 2.5
mm
6
3
1
2
4
5
AIR DAMPER ADJUSTMENT
(Fig. 12)
Fig. 12
S7033