COMMISSIONING AND MAINTENANCE
ONLY FOR GITRÈ B/100 MODELS
− Turn the boiler’s mains power switch ON;
− Set the room thermostat to the required temperature (~
20°C) or, if the system has a timer or timer-thermostat,
make sure that this is switched “ON” and adjusted to the
required temperature (~ 20°C).;
− Open the control panel access door;
− Adjust the boiler and storage cylinder thermostats to
about the middle of the section with three lines;
− Turn the Summer/Winter selector to (II) Winter;
20
40
60
80
100
0
120
20
40
60
80
100
0
120
− Turn the function selector to ON (I) and make sure that
the green power indicator lights.
20
40
60
80
100
0
120
The boiler now starts up and the burner remains lit until the
temperature setpoint is reached.
3.2.1
Ignition failure
If any ignition errors or malfunctions occur, the burner enters
“LOCKOUT”. This is shown by the red button light on the burner
and by the warning light on the control panel.
20
40
60
80
100
0
120
9
If a “LOCKOUT SHUTDOWN” occurs, wait about 30 seconds be-
fore resetting the burner.