background image

2915246

12 

GB

RATIO BETWEEN THE MINIMUM AND MAXIMUM OUTPUT

For a better explanation we suppose to have a burner with an adjustable output between the range 25 - 100. The ratio 
between the minimum and maximum output is generally included between 1 : 4 (25 - 100) and 1 : 3 (25 - 75); our burners 
leave the factory set for these ratio. If the ratio should be reduced at 1 : 2 (25 - 50 or 50 - 100) it is advisable to re-adjust 
the tension rods for the air and gas and the controlling sector of the gas throttle valve.

CONTROL OF THE GAS THROTTLE VALVE 
The  tension  rod  11)  moving  the  control  sector  of  the  throttle
valve is positioned - by the factory - on the hole marked 90° (90°
is  the  moving  angle  of  the  throttle  valve  when  the  cam  with
adjustable profile 6) covers the complete angle of 130°).
When the ratio between the minimum and maximum output is
approximately 1 : 2, the tension rod shall be positioned on the
hole marked 60° (60° is the moving angle of the throttle valve
when the cam covers 130°).
If the ratio 1 : 2 is in the lower outputs range (25 - 50) the change
from 90° to 60° of the tension rod will be sufficient.
Should  this  ratio  be  in  higher  range  (50  -  100)  in  this  case,
further to position the tension rod on 60° it shall be shortened.
Proceed as follows:
- Disjoint the articulation from the control sector.
- Screw down the tension rod on the extension.
- Reassemble the articulation on the control sector.
In this way the gas throttle valve - servomotor at 0° - is partially
open.
The  shortening  of  the  tension  rod  shall  permit  the  gas  flow
without  setting  the  3rd  cam  of  the  servomotor  too  forward,
because in this way the turn of the cam with adjustable profile
would be limited.

CONTROL OF THE AIR DAMPER
The length of the tension rod 13) adjusting the air damper can
be varied too.
If the air damper is moving, during the operation, into a reduced
angle (ratio 1 : 2 lower outputs range) it is necessary to extend
the tension rod.
In this way the cam profile is not too much bent.
When the burner is off proceed in this way:
- Disjoint the articulation 14) of the tension rod 13) from the lever
15).
- Extend the tension rod.
- Manually position the servomotor on 0°.
- Join the tension rod to the lever.
- Move the cam profile till the pointer placed on the air damper
shaft is at 0°.

Содержание GAS 5 P/M

Страница 1: ...Installation use and maintenance instructions 2915246 2 07 2016 Forced draught gas burner Progressive two stage or modulating operation CODE MODEL TYPE 3753581 GAS 5 P M 535 T80 GB...

Страница 2: ...M These products are in compliance with the following Technical Standards EN 676 EN 12100 and according to the European Directives MD 2006 42 EC Machine Directive LVD 2014 35 UE Low Voltage Directive...

Страница 3: ...ration two stages progressive modulating kit with controller available upon request Fuel natural gas Pci 8 10 kWh m3 7000 8600 kcal m3 Minimum gas pressure for maximum output 9 8 mbar are needed measu...

Страница 4: ...NS COMBUSTION CHAMBER PRESSURE MAXIMUM OUTPUT Min output 155 kW 133 300 kcal h Boiler front plate drilling Length available with special blast tube to be separately required Burner 160 160 165 M12 D17...

Страница 5: ...ain 550 kW it is necessary a gas pressure of 9 mbar and the combustion head set as indicated at page 8 If the combustion chamber is pressurized at 2 mbar the pressure detected at the testpoint 9 is 9...

Страница 6: ...Loosen the screws 2 unhook the tension rod of the air damper 1 remove the connecting lead of the servomotor withdraw the group A from the group B After the setting re assemble and verify that the ten...

Страница 7: ...out y the factory Key to layout CMV Motor contactor LFL Control box MB Burner terminal strip MV Fan motor PA Air pressure switch RT Thermal cut out SM Servomotor SO Ionisation probe SP Plug socket TA...

Страница 8: ...urner must be stopped every 24 hours of operation by means of an hours counter to be connected in series with the adjustment devices Key to layout BP Pressure probe BT Temperature probe MB Burner term...

Страница 9: ...ontroller modulating version 8 Pre sheared holeg Further prospective signals or controls can be connected to the burner wiring terminal board by removing the metal weld nuts from the pre sheared holes...

Страница 10: ...justment pressure by turning slowly clockwise the knob till reaching the burner lock out Thereafter turn the knob anticlockwise for 1 mbar and repeat the burner start up for checking the regularity if...

Страница 11: ...he plate 4 Tighten the screws 1 Gas setting Loosen the screw 5 move the ring 6 so that the pointer 7 is coincident with the desired setpoint 8 Tighten the screw 5 Attention the set point number is the...

Страница 12: ...controls the min stroke and remains al ways positioned on 0 in this way when the burner is off the air damper is totally closed Orange cam it controls the minimal modulating power It is set by the fa...

Страница 13: ...file 7 of the cam by gradually acting on the screws 9 MINIMAL OUTPUT SETTING Gas Disjoint the cam with adjustable profile 6 by means of the button 5 Turn manually anticlockwise the cam till to reach t...

Страница 14: ...ange 25 50 the change from 90 to 60 of the tension rod will be sufficient Should this ratio be in higher range 50 100 in this case further to position the tension rod on 60 it shall be shortened Proce...

Страница 15: ...TION CURRENT The minimum current necessary for the control box operation is 6 A The burner normally supplies a higher current value so that no check is needed However if a measurement of the ionizatio...

Страница 16: ...operation of the flame detecting circuit because of probe to earth defective internal amplifier Stop during pre purge phase because of The servomotor does not change over the minimal opening circuit i...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...Subject to modifications RIELLO S p A I 37045 Legnago VR Tel 39 0442 630111 http www riello it http www riello com...

Отзывы: