6
GENERAl INfoRMATIoN
Unit display
The unit display shows the active functioning mode, the tem-
perature and the alarms, if any.
1
Display
1
1
Temperature indication
2
Operating mode
1
2
2
Cooling mode enabled
Heating mode enabled
Not available
Dehumidification mode enabled
1. Detected ambient temperature
2. Required temperature when using the button
3. Alarm code
1.5
AMW ST
Unit description
R
AMW ST
is an indoor unit for wall installation, suitable
for use in residential and small business premises in combina-
tion with the outdoor unit. The multiple-speed fan DC motor
improves performance and sound comfort.
Control, setting and programming operations are carried out
with the IR remote control.
Safety and adjustment devices
The device safety and setting are achieved thanks to:
—
heat exchanger temperature sensor transmitting the de-
tected value to the control panel, which is trigged in case
of abnormal temperature with regard to the operating
mode
—
room air temperature sensor transmitting the detected
value to the control panel in order to control the operation
of the outdoor unit and regulate the room temperature
9
Safety device replacement must be carried out by
R
Technical Support Service, using only original components.
Please refer to the spare parts catalogue.
0
IT IS FORbIDDEN to operate the device with faulty safety sys-
tems.
Identification
The unit can be identified through the technical data plate:
0010596212
8.8 kg
Net Weight
Power supply
1PH,230V~,50Hz
Anti-electric shock
Class
I
Manufacture date
S.N.
MADE IN P.R.C.
Air volume
500 m³/h
Riello S.p.A- Via Ing. Pilade Riello, 7
37045 LEGNAGO (VR) - Italy
Model :
Code :
AMW 25 ST
20139544
Technical data plate
Contains the device's technical and performance data.
9
The tampering, removal, or absence of the identification
plates will not allow the product to be properly identified by
its serial number.