20032186
16
GB
Installation
5.8
Electrode setting
5.9
Nozzles installation
The burner complies with the emission requirements of the
EN 267 standard.
In order to guarantee that emissions do not vary, recommended
and/or alternative nozzles specified by the manufacturer in the In-
struction and warning booklet should be used.
5.9.1
Nozzles recommended
Monarch
type R
Delavan
type B
Steinen
type S
Danfoss
type S
WARNING
The position of the electrodes cannot be regulat-
ed. In case of failure, check that the measure-
ments as shown on the figure are respected.
WARNING
Before removing or assembling the nozzle, loosen
the screw A) (Fig. 11) and move the electrodes
ahead.
Move the electrode holder backwards to the end.
WARNING
Respect the positions shown in Fig. 11.
D6313
6,5
±
0,5 mm
A
4
±
0,3 mm
Fig. 11
WARNING
It is advisable to replace nozzles every year dur-
ing regular maintenance operations.
CAUTION
The use of nozzles other than those specified by
the Manufacturer and inadequate regular mainte-
nance may result into emission limits non-con-
forming to the values set forth by the regulations
in force, and in extremely serious cases, into po-
tential hazards to people and objects.
The manufacturing company shall not be liable for
any such damage arising from nonobservance of
the requirements contained in this manual.
Содержание 705M
Страница 2: ...Istruzioni originali Translation of the original instructions...
Страница 63: ......