18
TYPICAL SYSTEM SCHEMATIC
3
TYPICAL SYSTEM SCHEMATIC
EAF
PC
RI
1
UAC
PRS
EAF
1
6
MI
1
1
1
2
1
5 (*)
1
3
4
9
Do not use a check valve in the hydraulic connections to the heating system consumption points.
9
The safety valves must be connected to a suitable collection and drain system.
9
The selection and the installation of the components of the system is the responsibility of the installer, who must operate in
accordance with good practice and current Legislation.
9
If needed, water supplies and recovery circuits must be conditioned by suitable treatment systems. Refer to the values listed in
the table on page 26.
9
Domestic hot water and central heating circuits must be completed with expansion vessels of adequate capacity and suitable,
correctly-sized safety valves. The discharge of safety valves and appliances must be connected to a suitable collection and dis-
posal system (see Catalogue for compatible accessories).
0
It is prohibited to operate the circulators without water.
1
Isolating valve
2
Non-return valve
3
Pressure reducer
4
Water softener filter
5
DHW circulation pump
6
Expansion tank
PC
Thermal unit circulation pump
MI
Central heating flow
RI
Central heating return
UAC
Domestic hot water outlet
DRP
DHW recirculation preset
EAF
Domestic cold water inlet
(*)
Circulator pump not controlled by the thermal unit
regulator