background image

0

4

-3

7

1

H

B

0

1

E

G

User Manual

A00

NSA-002A

Содержание NSA-002A

Страница 1: ...04 371HB01EG User Manual A00 NSA 002A ...

Страница 2: ... may void the FCC authorization to operate this equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency ...

Страница 3: ... 2 3 Getting started 12 3 Mounting Options 12 3 1 Connecting Interfaces 12 3 2 Powering the Unit 13 3 3 Operation Mode 14 3 4 Web Interface 16 4 Stream consumer 17 4 1 Stream provider 18 4 2 General settings 19 4 3 Advanced 20 4 4 Appendix 21 5 Technical Drawing 21 5 1 Technical Specifications 22 5 2 Riedel NMOS Explorer 23 5 3 Service 24 5 4 Notes 25 5 5 Index 26 ...

Страница 4: ...t by Riedel Communications GmbH Co KG or its suppliers Riedel Communications GmbH Co KG gives no warranty of any kind with regard to this manual or the software including but not limited to the implied warranties of merchantability and fitness for a particular purpose Riedel Communications GmbH Co KG shall not be liable for any errors inaccuracies or for incidental or consequential damages in conn...

Страница 5: ...y to prevent the danger Warning Indicates a potentially hazardous situation which if not avoided could result in death or serious injury The highlighted line indicates the activity to prevent the danger Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices The highlighted line indicates ...

Страница 6: ...lectric shock do not remove cover or expose the products to rain or moisture Service All service has to be undertaken only by qualified Riedel service personnel Do not plug in turn on or attempt to operate an obviously damaged device Never attempt to modify the equipment components for any reason Caution All adjustments have been done at the factory before the shipment of the devices No maintenanc...

Страница 7: ...to dispose of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conse...

Страница 8: ...rated into AES67 networks The power can be supplied by mains and via the AES67 network if it supports PoE functionality 2 1 Product Elements figure 1 NSA 002A front figure 2 NSA 002A back Analog 4 wire inputs XLR3 6x Analog 4 wire outputs XLR3 6x Mode button 1x GPI inputs D Sub 9 female 3x Ethernet connectors RJ45 PoE 2x Power supply mains input 1x Status LEDs 3x GPO outputs D Sub 9 male 3x ...

Страница 9: ... Connection OK or idle not configured green blinking Connection configured but no data communication red Connection configured but mismatch between sender and receiver orange Synchronization errors This may happen during the first 5 min Check PTP settings Audio glitches may happen off All other cases PTP Status bottom green PTP slave PTP offset 1 µs green blinking PTP master orange PTP slave PTP o...

Страница 10: ...single ports 9 6 5 1 Pin Signal Pin Signal 1 GP IN1 P 6 GP IN1 N 2 GP IN2 P 7 GP IN2 N 3 GP IN3 P 8 GP IN3 N 4 GPIO 5V 9 GND 5 Chassis Chassis Chassis Figure 4 GPI IN connector Sub D 9 female pinout GND GPI INn P GPI INn N Figure 5 GPI IN connector schematic The input voltage range of the GPI inputs is 5 to 30 VDC 5 mA current draw internal optocouplers The polarity of the inputs is important The ...

Страница 11: ...y self healing fuse The polarity of the output has no preference The outputs are galvanically isolated The GPIO 5V output voltage drops when increasing the load 5V 0mA 3 3V 50mA ETH PoE ports The AES67 ports are used to connect the AES67 network to the NSA 002A The AES67 ports are 1000Base T compatible only Furthermore these ports can be used to power PoE IEEE 802 3af the NSA 002A 1 8 Pin Signal P...

Страница 12: ... 9 bumper assembly Rack Mount RMK 001 19 Rack Mount Kit Rack mount kit for rack installation of one or two devices combined together figure 10 19 rack assembly 3 2 Connecting Interfaces Connect your AES67 network with one of the two ETH ports of the NSA 002A figure 11 connecting AES67 network Connect your analog audio inputs and outputs with the corresponding interface of the NSA 002A figure 12 co...

Страница 13: ...that is attached to one ETH port b Via mains that is attached to the mains input Both power sources can be attached simultaneously for redundancy reasons Caution To shut down the unit completely remove the power cord and both Ethernet cables figure 13 powering via PoE figure 14 powering via mains ...

Страница 14: ...108 cards RSPs NSAs or other 3rd party AES67 devices To overcome this value implementation of boundary clock switches is recommended Bolero Mode The Bolero mode is used to easily adapt analog audio signals into Bolero networks Connect a NSA 002A direct or via switch to the AES67 Config port of the Bolero Antenna One additional NSA 002A may daisy chained via the internal switch if the NSA 002A is d...

Страница 15: ...ual mode is used to easily adapt analog audio signals into any AES67 networks Standalone operation as AES67 to analog converter Configuration via web interface Internal switch for daisy chaining Stream setup 1 stream 6 channels figure 16 Manual Mode ...

Страница 16: ... the NSA 002As web interface open a web browser on your computer and point it to the IP address of the NSA 002A The NSA 002A web interface appears figure 17 NSA 002A web interface When the user changed a parameter the Apply all button becomes active After changing all desired parameters the user can press this button to apply all changes The Clear all or Discard changes button discards all changes...

Страница 17: ...ection determines the channel that is output on the respective XLR output Show Advanced settings Manuel path of the Bonjour streams Manual SDP Opens a dialog to import a SDP of a 3rd Party Sender i e Artist Status Each channel shows its status next to the channel number IDLE No stream is configured WAITING Stream configured but not received RECEIVING MULTICAST SYNTONIZED Configured multicast strea...

Страница 18: ...me Name of the streams Activate Activates the respective stream after clicking the Apply all button SDP Shows the session descriptions Status Shows the state of the respective channel see Status in chapter Stream consumer Multicast Address Port Fields for manual configuration of the multicast addresses and ports Use automatic configuration If enabled the multicast addresses of the streams are numb...

Страница 19: ...lly Audio mode Manual Bolero Toggles between Manual and Bolero Mode Use the devices key to change the mode Audio configuration Sampling Rate Fixed sample rate of 48 kHz Resolution Receiver delay Samples Number of samples in the audio buffer Syntonized mode In Synton mode audio packets without or with invalid PTP timestamps are processed and output hence this mode can be used in networks without PT...

Страница 20: ...et Domain Allows entering a PTP domain Prefered master Sets the PTP priority 1 and 2 to 20 Slave only Blocks the device to be used as synchronization master SIP configuration Allows setting the SIP username if SIP connections are desired SAP configuration SAP browsing enabled Shows also Dante AES67 Streams in the Stream consumer tab Multicast Adress Port Session Timeout Specific configuration of t...

Страница 21: ...21 NSA 002A User Manual A00 5 Appendix 5 1 Technical Drawing figure 22 NSA 002A top figure 23 NSA 002A side ...

Страница 22: ...n 24 bit GPI input 3x Galvanically isolated opto coupler inputs Isolation voltage 100 VDC Max voltage 30 VDC Input current 5 mA 5 VDC Switching threshold off 0 8 VDC on 2 0 VDC GPO output 3x Galvanically isolated solid state relay outputs Isolation voltage 100 VDC Max voltage 30 VDC Max current 100 mA Power supply Mains 100 240 V 50 60 Hz max 0 6 A inrush current PoE IEEE 802 3af type 1 42 57 V Po...

Страница 23: ...ge SDP objects Download the NMOS Explorer from the Riedel website and install it on your windows PC Ø After starting the NMOS Explorer 1 Select the index Bonjour 2 If necessary select your network adaptor in the field Network Interface that is attached to the NSAs network Limit the amount of results by entering http in the field Service Type and NSA in the field Service Name 3 Click on the magnifi...

Страница 24: ... 9400 Monday Friday 8am 5pm Central European Time Fax 49 0 202 292 9419 Or use the contact form on our website www riedel net Company Contact Wuppertal Headquarters For repairs please contact your local dealer Your dealer will be able to help process your repair as fast as possible and or arrange for the delivery of spare parts The address for repairs sent directly to Riedel Communications GmbH is...

Страница 25: ...25 NSA 002A User Manual A00 5 5 Notes ...

Страница 26: ...ess Port 18 Multicast Adress Port Session Timeout 20 N Name 17 Network configuration 19 NMOS Explorer 23 Notes 25 NSA 001D Technical Drawing 21 NSA 001D Technical Specifications 22 O Operation Mode 14 Output Voltage GPIO 10 P pinout 11 PoE port 11 Polarity GPI IN port 10 Polarity GPI OUT port 11 Ports Pinouts 10 Powering the unit 13 Preface 4 Prefered master 20 Product Elements 8 PTP 20 R Receiver...

Страница 27: ...ub D 9 male 11 Switching Power GPI OUT port 11 Symbols 5 Syntonized mode 19 T Technical Drawing NSA 001D 21 Technical Specifications NSA 001D 22 Telephone 24 Trainings 24 U Use automatic configuration 18 V Voltage GPI OUT port 11 Voltages GPI IN port 10 W Web Interface 16 X XLR 3 10 ...

Страница 28: ...www riedel net Riedel Communications GmbH Co KG Uellendahler Str 353 42109 Wuppertal Germany ...

Отзывы: