PRODUCT SPECIFICATIONS
ENGINE
Engine Type ...........................Yamaha MZ360, 357cc, OHV
Fuel Volume ................................................................ 8 gal.
GENERATOR
Rated Voltage .....................................................120V/240V
Rated Amps ..........................................................56.7/28.3
FEATURES
Rated Running Watts* ............................................6,800 W
Rated Starting Watts ..............................................8,500 W
Rated Frequency ........................................................60 Hz
DIMENSIONS
Length ........................................................................ 30 in.
Width ....................................................................... 28.2 in.
Height ...................................................................... 25.7 in.
Weight .................................................................... 221 lbs.
KNOW YOUR GENERATOR
See Figure 2.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AC CIRCUIT BREAKER
The circuit breaker is provided to protect the generator
against electrical overload. The circuit breaker may be reset
by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
CHOKE LEVER
The choke lever is used when starting the engine.
ENGINE SWITCH
The engine switch is used in combination with the recoil
starter grip to start the engine. It is also used to turn the
engine off.
FUEL TANK
The fuel tank has a capacity of 8 gallons.
FUEL VALVE
Fuel flow from the fuel tank to the engine is turned on and
off using the fuel valve.
GenSmart™ MONITORING SYSTEM
The GenSmart monitoring system tracks usage and load
and alerts the operator when periodic engine maintenance
is needed.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock.
Consult with a qualified local electrician for grounding
requirements in your area.
IDLE CONTROL SWITCH
When running a load of more than 300 watts, turning on the
idle control switch will allow the generator to sense when no
load is present. In response, the generator will begin idling at
a lower RPM, which will help conserve gasoline and lessen
the noise being produced by the generator.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, the oil drain plug is
removed to allow old engine lubricant to be drained.
RECEPTACLES
The following single phase, 60 Hz outlets on the control panel
can be used for operating appropriate equipment, electrical
lighting, tools, and motor loads: two 120 Volt AC duplex GFCI
20 Amp receptacles and one 240 Volt AC, 30 Amp recep-
tacle.
RECOIL STARTER GRIP
The recoil starter is pulled to start the machine.
*Rated running watts determined by PGMA Standard G200
Содержание RD906814P