![RIDGID R48607 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/ridgid/r48607/r48607_operators-manual_1458801016.webp)
16 - English
Lift the miter lock lever to unlock the miter table.
Press the miter detent bypass and rotate the miter table
to the left 30° position on the miter scale as shown in
figure 15.
Tighten the remaining screw to secure the miter scale
detent plate.
ASSEMBLY
SQUARING THE BLADE TO THE MITER TABLE
See Figures
20
-
22
To square the blade at 0°:
Remove the battery pack from the tool.
Pull the saw arm all the way down and engage the lock
pin to hold the saw arm in transport position.
0
15
30
22.5
MITER
TABLE
MITER
TABLE
VIEW OF BLADE NOT SQUARE WITH FENCE,
ADJUSTMENTS ARE REQUIRED
FIXED
MITER
FENCE
FRAMING
SQUARE
BLADE
Fig. 17
Fig. 16
Fig. 19
SCALE
INDICATOR
VIEW OF BLADE NOT SQUARE WITH FENCE,
ADJUSTMENTS ARE REQUIRED
SLIDING
MITER
FENCE
FRAMING
SQUARE
BLADE
Fig. 18
MITER DETENT
BYPASS BUTTON
(PRESS TO
DISENGAGE)
UNLOCKED
0
15
30
22.5
MITER SCALE
DETENT PLATE
PRESS THE MITER DETENT BYPASS TO
ROTATE THE MITER TABLE
Содержание R48607