15
ADJUSTMENTS
ALIGN THE BLADE TO TABLE
Your saw is calibrated at the factory to cut true. Over time the
saw’s calibration may drift and will need to be re-calibrated.
See Figure 11.
1.
Unplug the Saw
2.
Lower the saw head all the way down to the transport
position and engage the saw head lock pin to hold it in
place. Push the saw head into the fully retracted
position and engage the slide lock lever
F15
to hold it in
place.
3.
Set the miter position to 0° and engage the miter lock
knob so the table will not move.
4.
Set the bevel position to 0°. Engage the bevel detent
latch
F27
, located on back, so the detent pin locks into
the bevel detent plate.
5.
Place a combination square
A
against the table and
the face of the saw blade .
NOTE:
Make sure the square contacts the flat part of the
blade and not the teeth.
6.
Rotate the blade by hand and check the blade-to-table
alignment at several points. If the blade face is not flush
with the square you will need to adjust the bevel detent
plate
F5
.
7.
Loosen the three screws
B
and adjust the bevel
detent plate position. Set so the table and blade are
flush against the combination square. Make sure the
bevel lock/unlock handle is not locked, so the detent
plate may be adjusted.
8.
Re-tighten the three screws and re-check the blade-to-
table alignment.
NOTE:
After squaring adjustment has been made, it may be
necessary to loosen the indicator screw
C
, shown in Figure
11, and reset it to zero.
lock
unlock
Figure 11
A
F5
F15
B
C
Содержание R4231