Safety Symbols

In this operator’s manual and on the product, safety symbols and signal words are used to
communicate important safety information. This section is provided to improve understand-
ing of these signal words and symbols.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey
all safety messages that follow this symbol to avoid possible injury or death.

DANGER indicates a hazardous situation which, if not avoided, will result in death or
serious injury.

WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.

CAUTION indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.

NOTICE indicates information that relates to the protection of property.

This symbol means read the operator’s manual carefully before using the equipment. The op-
erator’s manual contains important information on the safe and proper operation of the equip-
ment.

This symbol means always wear safety glasses with side shields or goggles when handling
or using this equipment to reduce the risk of eye injury.

This symbol indicates the risk of hands, fingers or other body parts being caught or wrapped
in gears or other moving parts.

This symbol indicates the risk of electrical shock. 

Do not expose equipment to rain or
wet conditions.

Water entering equip-

ment will increase the risk of electrical
shock.

Personal Safety

Stay alert, watch what you are doing
and use common sense when operat-
ing equipment. Do not use equipment
while you are tired or under the influ-
ence of drugs, alcohol or medication.

A

moment of inattention while operating
equipment may result in serious personal
injury.

Do not overreach. Keep proper footing
and balance at all times.

This enables

better control of the power tool in unex-
pected situations.

Use personal protective equipment.

Always wear eye protection. Protective
equipment such as dust mask, non-skid
safety shoes, hard hat or hearing protec-
tion used for appropriate conditions will
reduce personal injuries.

Equipment Use and Care

Do not force equipment. Use the correct
equipment for your application.

The cor-

rect equipment will do the job better and
safer at the rate for which it is designed.

2

micro CA-100 Inspection Camera

General Safety
Information

WARNING

Read all safety warnings and instruc-
tions. Failure to follow the warnings and
instructions may result in electric shock,
fire and/or serious injury.

SAVE THESE INSTRUCTIONS!

Work Area Safety

Keep your work area clean and well lit.

Cluttered or dark areas invite accidents.

Do not operate equipment in explosive
atmospheres, such as in the presence
of flammable liquids, gases or dust.

E-

quipment can create sparks which may
ignite the dust or fumes.

Keep children and by-standers away
while operating equipment.

Distractions

can cause you to lose control.

Electrical Safety

Avoid body contact with earthed or
grounded surfaces such as pipes, radi-
ators, ranges and refrigerators.

There is

an increased risk of electrical shock if your
body is earthed or grounded.

NOTICE

DANGER

WARNING

CAUTION

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание micro CA-100

Страница 1: ...ully before using this tool Failure to understand and follow the contents of this manual may result in electri cal shock fire and or serious personal injury micro CA 100 Operator s Manual www GlobalTe...

Страница 2: ...4 Controls 4 FCC Statement 5 Electromagnetic Compatibility EMC 5 Tool Assembly Changing Installing Batteries 5 Installing Imager Head Cable or Extension Cables 5 Installing An Accessory 6 Pre Operati...

Страница 3: ...when operat ing equipment Do not use equipment while you are tired or under the influ ence of drugs alcohol or medication A moment of inattention while operating equipment may result in serious perso...

Страница 4: ...hile op erating or handling the micro CA 100 Inspection Camera This will help prevent contamination with toxic or infectious ma terial Do not use equipment if the switch does not turn it ON and OFF An...

Страница 5: ...Specifications and Standard Equipment Description The micro CA 100 Inspection Camera dis plays live color video from an imaging sensor and light source that s connected to a 3 flex ible cable It can...

Страница 6: ...f not in stalled and used in accordance with the in structions may cause harmful interference to radio communications However there is no guarantee that interfer ence will not occur in a particular in...

Страница 7: ...ring the in spection do not use the inspection cam era until it has been properly serviced 10 With dry hands re install the battery hold er making sure to fully insert Figure 5 Cable Connections 3 and...

Страница 8: ...a complete listing of RIDGID products see the RIDGID catalog online at 3 Make sure the micro CA 100 Inspection Camera has been properly inspected before each use 4 Install the correct accessories for...

Страница 9: ...mager head and cable into the space to be inspected Do not use the imager head or cable for anything other than an inspection de vice Do not use the imager head and cable to clear a path Do not force...

Страница 10: ...and Repair WARNING Improper service or repair can make the RIDGID micro CA 100 Inspection Camera unsafe to operate Service and repair of the micro CA 100 In spection Camera must be performed by a RID...

Страница 11: ...lay turns itself OFF after a brief period Unit will not turn ON Troubleshooting Loose cable connections Imager is broken Battery low on power Dead batteries Unit need to be reset Check cable connectio...

Отзывы: