the laser beam must rotate counterclockwise to align with the plumb line, so
you need to press the
button.
4. Press the
button to save the calibration, press
button repeatedly
to exit from calibration mode.
5. Now repeat the Z axis checking to insure you have made the correct
calibration.
TROUBLESHOOTING
PROBLEM POSSIBLE
CAUTION
SOLUTION
Laser dot/line
projected is
weak, hard to
see
1. Battery is depleted.
2. The tool is out of the
operating temperature
range.
3. The tool is too far from
the target.
4. Working condition is too
bright.
1. Replace with new batteries or
run it with AC/DC adapter.
2. Make sure that the tool
operating temperature is
within 32°F to 104°F.
3. Move the tool closer to the
target.
4. Use green laser-enhancing
glasses and green-laser
detector to locate the laser
position.
Laser dot/line is
not projected
1. The tool is put in sleep
mode.
2. The tool is performing
leveling adjustment
automatically.
3. The tool suffers a sudden
shock
4. The tool is out of the
operating temperature
range.
1. Wake up the tool with the
remote control or turn off and
on again.
2. Wait until the Auto leveling
adjustment is finished.
3. Wait until the tool re-levels
automatically.
4. Make sure the tool operating
temperature is within 32°F to
104°F.