background image

32DSSK03.B

 

1 - 1 

I

KLEARVUE PRIVATE USE WHEELCHAIR LIFT INTRODUCTION 

 his manual provides operating and maintenance instructions for the Ricon K-series Klear-

Vue Private Use wheelchair lift

.  

The platform on the KlearVue splits horizontally to reduce 

overall lift height when it is stowed.  This results in a less obstructed view, either into or out 

of the vehicle. 

The lift is intended to provide wheelchair access to personal vehicles and to motor homes.  The 

mechanical linkages provide smooth movement to the platform, which has a rated load capacity 
of 600 pounds (273 kilograms).  The lift can be operated by the wheelchair occupant or by a 
trained assistant. 
The lift contains an electro-hydraulic pump with a built-in manual backup pump

.  

If the lift loses 

power, it can be raised or lowered manually.  A control pendant is used to unfold the platform 
out from the vehicle (deploy)

.  

The passenger boards the non-skid platform and an operator low-

ers the platform to the ground

.  

After the passenger departs, the platform is raised and folded 

back into the vehicle (stow)

.  

The platform splits and folds horizontally when stowed. 

It is important to passenger safety that these operating instructions be read and understood by 
the lift operator

.  

It is also important that the Ricon recommendations for cleaning, inspecting, 

and lubricating the wheelchair lift be followed. 

A. PRODUCT 

SUPPORT 

If there are questions about this manual, or you need copies, please contact Ricon Product Sup-

port at the following location: 

Ricon Corporation 
7900 Nelson Road 
Panorama City, CA 91402 
Telephone:...............................................................................................(818) 267-3000 

 

............................................................................................(800) 322-2884 

 
 

World Wide Website:   www.riconcorp.com 

T

Содержание 32DSSK03

Страница 1: ...PRINT K Series KlearVue DOT Private Use Lift OPERATOR MANUAL 08 02 05 32DSSK03 B 1995 2005RICONCORPORATION All Rights Reserved U S and Foreign Patents Pending Printed in the United States of America...

Страница 2: ...OT Private Use Lift verifies that this plat form lift meets only the private use lift re quirements of FMVSS no 403 This lift may be installed on all vehicles appropriate for the size and weight of th...

Страница 3: ...SION RECORD REV PAGES DESCRIPTION OF CHANGE ECO 1 1 2 2 2 9 Listed weight has changed to 600lbs 1 4 2 4 Changed pendant type to universal p n 14727 32DSSK03 B 3 3 Changed Max Load decal to 600lb 26183...

Страница 4: ...INDICATORS 2 4 CONTROL PENDANT 2 4 CIRCUIT BREAKERS AND INDICATOR LIGHTS 2 5 BRIDGEPLATE LOAD SENSOR 2 6 THRESHOLD WARNING SYSTEM 2 7 MANUAL BACK UP PUMP 2 7 LIFT CYCLE COUNTER 2 8 E NORMAL LIFT OPER...

Страница 5: ...32DSSK03 B iv This page intentionally left blank...

Страница 6: ...manual backup pump If the lift loses power it can be raised or lowered manually A control pendant is used to unfold the platform out from the vehicle deploy The passenger boards the non skid platform...

Страница 7: ...s of nature i e weather lightning flood NOTE Ricon recommends that this product be inspected by an authorized Ricon service technician at least once every six months or sooner if necessary Required ma...

Страница 8: ...eration Exercise caution when operating lift to avoid injury and be certain that hands feet legs or clothing are not in path of the platform as it moves Read and thoroughly understand the operating in...

Страница 9: ...STOW DEPLOY BASEPLATE PUMP HANDLE MANUAL BACKUP REAR POWER UNIT HYDRAULIC CYLINDER HYDRAULIC TOP AND BOTTOM ARMS RIGHT VERTICAL ARM ARMREST PLATFORM LINKAGE FOLDING HINGES PLATFORM ROLLSTOP FRONT FRON...

Страница 10: ...age Front rollstop Front barrier prevents wheelchair from inadvertently rolling off of platform during platform movement Hydraulic cylinder left and right Telescoping single acting cylinders convert h...

Страница 11: ...efer to Table 1 2 for the dimensions that correspond to your lift model TABLE 1 2 K SERIES OPERATING VOLUME DIMENSIONS inches mm s MODEL A B C K1203 30 762 51 1 295 30 762 K1205 32 813 51 1 295 30 762...

Страница 12: ...t if unsafe conditions are present or unusual noises or movements are noticed Contact an authorized Ricon dealer for repair if necessary Read and comply with all warning labels and symbols affixed to...

Страница 13: ...ng platform power chair users should turn off power and set brake Use great care in wet conditions because the wheelchair brakes are less effective if wheels or platform are wet Never leave platform o...

Страница 14: ...lowers opens when platform reaches ground level UP Platform rises from ground level towards vehicle floor level The front rollstop automatically rises closes when platform leaves ground level STOW Pla...

Страница 15: ...towards the ground Pushing the UP button causes the platform to rise towards floor level Pushing the STOW button when the platform is at floor level causes it to fold and retract into the vehicle Plat...

Страница 16: ...ht is interfaced with the electrical system so that regardless of which interlock system is used the light will be on when the interlock provides power to lift and off when interlock has removed power...

Страница 17: ...System Circuit Breaker is located on the hydraulic pump as sembly In the event of a short circuit in the control system the circuit breaker button will pop out If pressing and releasing button does no...

Страница 18: ...argin of safety for lift users by warning them if the platform is below floor level The platform must be at floor level when boarding the platform prior to exiting the vehicle MANUAL BACK UP PUMP Refe...

Страница 19: ...visible through a slot on the rear side The counter advances each time the platform moves through a complete cycle which consists of the platform moving from the vehicle floor to the ground and back t...

Страница 20: ...ide space for lift operation and passenger boarding The lift operator must take special care to be certain that area is clear before deploying lift Be certain there are no obstacles beneath platform O...

Страница 21: ...icle and lock wheelchair brakes CAUTION Do not stand on bridgeplate as platform lowers c LOWER PLATFORM Push and hold DOWN button until platform is at ground level and front rollstop is fully lowered...

Страница 22: ...NG MANUAL BACKUP SYSTEM TO ENTER OR EXIT VEHICLE NOTE The threshold warning system is not active during manual operation and cannot be used to indicate platform height 1 DEPLOY PLATFORM a Refer to Fig...

Страница 23: ...evel of interior floor turn valve clock wise to close do not over tighten valve Do not lower platform below vehicle floor level The rear edge of bridgeplate must rest flat on vehicle floor e Load Pass...

Страница 24: ...ease wheelchair brakes and carefully exit platform 3 STOW PLATFORM a Refer to Figure 2 13 Verify that pump release valve is closed do not over tighten valve b Refer to Figure 2 14 Insert pump handle i...

Страница 25: ...32DSSK03 B 2 14 This page intentionally left blank...

Страница 26: ...areas where roads are salted in winter Verify that lift pivot points are clean and dry prior to lubrication C MAINTENANCE SCHEDULE Refer to cycle counter located on rear side of hydraulic power unit U...

Страница 27: ...nd add fluid when platform is at ground level Fluid that is added when platform is raised will overflow when platform is lowered Hydraulic power unit Verify that pump hydraulic fluid level is at FULL...

Страница 28: ...ground level Proceed to center of platform and face outward if possible LOCK WHEELCHAIR BRAKES Release wheelchair brakes and enter vehicle Press and hold UP button to raise platform to vehicle floor...

Страница 29: ...32DSSK03 B 3 4 This page intentionally left blank...

Отзывы: