• To exit from the service mode or return to the previous menu, select "Exit".
Service Mode Settings
Setting Item
Description
System Hours
The projector’s cumulative time that it has been switched on.
LED Hours
The LED’s cumulative operation time.
LED Hours (low)
The LED’s cumulative operation time in low power mode.
Factory Reset
Use this to reset all the settings in the OSD menu (except for
the service mode and network settings).
Burn In Test
Choose this option and press the Enter key to go into the Burn
in test menu.
Failure Log
Records the times of failures, such as excessive temperature.
Analog Settings
To execute PC Calibration.
LED Calibration Settings
To execute LED Calibration.
Optical Settings
Execute Spoke mode and test patterns.
Thermal Settings
Shows thermal status.
Other Settings
For RD testing only.
G Sensor Calibration
Use this to calibrate the sensor that detects the projector's
orientation.
Security Password
Show the Security password.
Exit
Exit the service mode.
4. Adjustment
42
Содержание WXC1110 Y0AB
Страница 1: ...Kaus PJ1 RICOH PJ RICOH PJ WXC1110 Machine Codes Y0AB Field Service Manual May 2016...
Страница 2: ......
Страница 7: ...1 Product Information Overview Main Unit 5...
Страница 20: ...1 Product Information 18...
Страница 24: ...2 Installation 22...
Страница 25: ...3 Replacement Equipment Needed 1 Screw Driver No 00 2 Screw Driver No 1 3 Screw Driver 2 5mm 4 Projector 23...
Страница 33: ...2 FPC cable A Multimedia Board 1 Top Cover page 25 2 FPC Cable page 30 Part Replacement 31...
Страница 34: ...3 Multimedia Board A 4 1 6 x4 Keypad 1 Top Cover page 25 2 Multimedia Board page 31 3 Keypad A 3 Replacement 32...
Страница 35: ...Engine Module 1 Bottom Cover page 28 2 Remove screws M1 6 4 x3 Part Replacement 33...
Страница 36: ...3 Engine Module with Focus Ring A 4 Focus Ring A M1 7 4 x3 Fans 1 Engine Module page 33 3 Replacement 34...
Страница 38: ...Main Board 1 Engine Module page 33 2 Remove three fans x3 page 34 Fans 3 Main Board A 3 Replacement 36...
Страница 39: ...Adjustable Foot 1 Adjustable foot A Part Replacement 37...
Страница 40: ...3 Replacement 38...
Страница 48: ...3 Select G Sensor Calibration G Sensor Calibration must have a value it must not be blank 4 Adjustment 46...
Страница 50: ...4 Adjustment 48...
Страница 51: ...5 Troubleshooting Troubleshooting Main Procedure 49...
Страница 52: ...No Power Troubleshooting 5 Troubleshooting 50...
Страница 53: ...Power Troubleshooting Troubleshooting 51...
Страница 54: ...Image Performance Troubleshooting 5 Troubleshooting 52...
Страница 55: ...Troubleshooting 53...
Страница 56: ...Remote Control Troubleshooting 5 Troubleshooting 54...
Страница 60: ...5 Troubleshooting 58...
Страница 64: ...4 Click Next 5 Click Next 6 Click Next 6 Firmware Update 62...
Страница 68: ...10 Select Preferences in the Edit menu 11 Click Communications 1 Select USB 2 Click OK 3 6 Firmware Update 66...
Страница 75: ...2 Click Update 1 Click Firmware 2 Select the FW upgrade file Bin 3 Click Open 4 AM8250 Firmware Upgrade 73...
Страница 76: ...3 Click Download 4 The success information will appear on screen 6 Firmware Update 74...
Страница 78: ...MEMO 76 EN...