3927
TonerEndJudg
This SP code determines whether the machine disables printing when the machine detects
toner end.
• Even when toner end is detected, there is a small amount of toner left in the AIO. If
a user wants to print with the AIO until all toner is used up, then set this SP to 1. But
then, there is no toner end detection, and the user must watch the print quality and
change the AIO when prints become too pale.
[0 to 1/0/1]
0: Yes (Printing stops when toner end is detected.)
1: No (Printing can continue even after toner end is detected.)
SP5-xxx: Mode
5024
mm/inch Display Selection
Selects the unit of measurement.
After selection, turn the main power switch off and on.
0: Europe/Asia (mm), 1: North America (inch)
5051
Toner Refill Displ
Toner Refill Detect Display
This SP switches on/off the message that prompts the operator when it is necessary to
replenish toner in the machine.
0: enable (Message displayed (Default))
1: disable (Message not displayed)
5055
Display IP add
Display IP Address
Switches the banner display of the IP address off and on.
[0 to 1/0/1] 0= No, 1= Yes
For example, if this SP is switched on, the IP address will be displayed below "Ready"
while the printer is in standby mode:
Ready
169.254.187.055
5302
Set Time
5. Service Tables
92
5
Содержание S-P2
Страница 1: ...Model S P2 Machine Code M001 SERVICE MANUAL September 2008 Subject to change ...
Страница 2: ......
Страница 12: ...10 ...
Страница 15: ... Never place anything on the power cord Installation Requirements 13 1 ...
Страница 22: ...2 Preventive Maintenance 20 2 ...
Страница 36: ...3 Replacement and Adjustment 34 3 ...
Страница 38: ...Toner End Sensor 1 Remove the AIO 2 Toner end sensor A hooks x 4 x 1 3 Replacement and Adjustment 36 3 ...
Страница 49: ...Main Motor 1 Left cover Left Cover 2 Main motor A x 4 x 1 Main Motor 47 3 ...
Страница 54: ...3 Replacement and Adjustment 52 3 ...
Страница 56: ...4 PSU fan with the bracket A x 1 x 2 5 PSU fan B x 2 3 Replacement and Adjustment 54 3 ...
Страница 82: ...4 Troubleshooting 80 4 ...
Страница 166: ...5 Service Tables 164 5 ...
Страница 168: ...Paper Path A Optional duplex unit B Standard paper tray unit C Optional paper tray unit 6 Details 166 6 ...
Страница 197: ... Any operation panel keys pressed Image Fusing and Paper Exit 195 6 ...
Страница 207: ...Controller Specifications Controller Specifications 205 7 ...
Страница 208: ...Controller Board 1 DDR DIMM I F 7 Specifications 206 7 ...