Machine Level
Front to back:
Within 5 mm. (0.2 inches) of level.
Right to left:
Within 5 mm. (0.2 inches) of level.
Required Space
Place the machine near the power source, providing the clearance as shown below:
A: Over 10 cm (4 inches)
B: Over 10 cm (4 inches)
C: Over 40 cm (15.8 inches)
D: Over 10 cm (4 inches)
Power Supply
• Make sure the plug is firmly inserted in the outlet.
• Avoid multi-wiring.
• Be sure to ground the machine.
Input voltage level
NA: 120 volts, 60 Hz
EU: 220-240 volts, 50 Hz/60 Hz
Permitted voltage
Fluctuation: ±10 %
1. Installation
12
1
Содержание S-P2
Страница 1: ...Model S P2 Machine Code M001 SERVICE MANUAL September 2008 Subject to change ...
Страница 2: ......
Страница 12: ...10 ...
Страница 15: ... Never place anything on the power cord Installation Requirements 13 1 ...
Страница 22: ...2 Preventive Maintenance 20 2 ...
Страница 36: ...3 Replacement and Adjustment 34 3 ...
Страница 38: ...Toner End Sensor 1 Remove the AIO 2 Toner end sensor A hooks x 4 x 1 3 Replacement and Adjustment 36 3 ...
Страница 49: ...Main Motor 1 Left cover Left Cover 2 Main motor A x 4 x 1 Main Motor 47 3 ...
Страница 54: ...3 Replacement and Adjustment 52 3 ...
Страница 56: ...4 PSU fan with the bracket A x 1 x 2 5 PSU fan B x 2 3 Replacement and Adjustment 54 3 ...
Страница 82: ...4 Troubleshooting 80 4 ...
Страница 166: ...5 Service Tables 164 5 ...
Страница 168: ...Paper Path A Optional duplex unit B Standard paper tray unit C Optional paper tray unit 6 Details 166 6 ...
Страница 197: ... Any operation panel keys pressed Image Fusing and Paper Exit 195 6 ...
Страница 207: ...Controller Specifications Controller Specifications 205 7 ...
Страница 208: ...Controller Board 1 DDR DIMM I F 7 Specifications 206 7 ...