RICOH Ri 1000
User Manual
140
3)
Horizontal banding -
thick horizontal lines
across the entire shirt
Nozzles 100% - appears in solid
colors of dark or gray - bi
directional banding - has to do
with the colors laying down in
different sequence depending on
which direction the carriage is
traveling
Uncheck the bi directional box in the RIP.
Nozzles 100% - appears in solid
colors - the color is inconsistent in
the scanning direction of the
carriage. This is caused by the
different drops of CMYK not
combining consistently
This can show in Speed Quality mode for
CMYK - Print in Fine Quality mode for
CMYK - if still persists - print in 1200 X
1200 dpi (Kothari RIP) or Superfine
4)
Several nozzles out –
improves not at all or
just a little with head
normal and strong head
cleans
During an initial ink fill - air has
been introduce to the head or
after a head clean cleaning fluid
or air was inadvertently pushed
into the head by the cleaning
applicator
Let the printer sit overnight which will
give the air a chance to settle – after the
nozzle should be good
5)
Dark shirt prints look
dull
White nozzles 100 % or near
100%. - In adequate amount of
pretreat on shirt - this can cause
the white ink to mostly sink into
the shirt
Increase the amount of pretreat being
sprayed on the shirt
White nozzles 100 % or near
100% but look dull. - White ink
has settled
If the white cartridges have not been
agitated per instructions - will need to
agitate the white ink cartridges for 2
minutes. Then perform 3 to 4 strong
head cleans - this will replace most of the
settled ink
Missing many nozzles on one or
both white heads
Perform head cleans to recover the
nozzle to 100% or near 100%
6)
Light shirt looks too dull
Nozzle is 100% - Wrong output
profile is selected
If printing in 600 X 600 Dpi and using a
profile meant for 1200 X 1200 DPI then
the shirt will look dull
7)
Cartridge reads 0% but
was just at a high %
(example 65%) at the
previous
operation.
(before
printing
or
before cleaning)
Temporary loss of Comm caused
cartridge reading error
Pull out the cartridge that reads 0%. The
status should change to NC and the
cartridges not loaded message will
appear in the status bar. Put the
cartridge back in and the % reading
should go back to normal. If the % still
reads 0 after reinserting the cartridge
then turn the printer off and turn it back
on and the cartridge will read correctly
Содержание Ri 1000
Страница 5: ...5 ...
Страница 11: ...RICOH Ri 1000 User Manual 11 Printer Specifications ...
Страница 12: ...RICOH Ri 1000 User Manual 12 1 2 Part Identification ...
Страница 27: ...RICOH Ri 1000 User Manual 27 Select PROGRAM and click NEXT ...
Страница 29: ...RICOH Ri 1000 User Manual 29 Select the ALLOW THE CONNECTION radial button and click NEXT ...
Страница 31: ...RICOH Ri 1000 User Manual 31 Name the rule and add a description optional then select FINISH when completed ...
Страница 64: ...RICOH Ri 1000 User Manual 64 Selecting ICC Preview ...
Страница 90: ...RICOH Ri 1000 User Manual 90 After agitating cartridges insert the cartridges ...