PC Calibration
After replacing the Main Board, PC Calibration should be done as well.
• Test equipment: video generator
• Test signal analog: 800 x 600@60Hz
• Test Pattern:94% White (up)/6% Black (down) (See below.)
Calibration Procedure
1.
Get into service mode. (
page 68 "How to Enter the Service Mode"
)
2.
Choose "Analog Settings" and press the "Enter" button.
3.
Select "PC Calibration".
When "Success" appears, it means "PC Calibration" is OK.
Calibration
75
Содержание PJ KU600
Страница 2: ......
Страница 9: ...Firmware Update Procedure 105 Updating the Network Firmware 105 Version Check after Updating 107 7...
Страница 10: ...8...
Страница 11: ...1 Introduction Overview Specifications Refer to the user s manual 9...
Страница 22: ...2 Replacement 20...
Страница 23: ...1 Only for WUXGA model Replaceable Part Hierarchy 21...
Страница 24: ...Equipment Needed 1 Screw bit No 2 or No 1 2 Screw bit No 0 3 Hex sleeves 5 mm 4 Projector 2 Replacement 22...
Страница 27: ...2 Remove the lamp cover A 3 Remove the protection sheet A 4 Disconnect the connector 1 Part Replacement 25...
Страница 33: ...4 Remove the color wheel module A 4 Photo Sensor 1 Remove the photo sensor A 1 Part Replacement 31...
Страница 35: ...3 Disconnect the connector 1 4 Remove the 2 screws x 2 Part Replacement 33...
Страница 59: ...6 Remove the cushion A which is fixed with adhesive at the bottom 7 Remove the 6 screws x6 Part Replacement 57...
Страница 88: ...2 Select Factory Reset and then press the Enter key 3 Select OK and press Enter key 4 Adjustment 86...
Страница 91: ...4 Click Next 5 Click Next 6 Click Next System Firmware Update 89...
Страница 94: ...For 64bit OS Microsoft WinUSB 3 Click Next 5 Firmware Update 92...