2. Energy Saving
2.2 Overview – 2 (System Settings)
20 sec.
1 to 240 min.
1min
Auto Off Timer
Off/Sleep Mode
1sec.
10 sec to 240 min.
1min
Panel Off Timer
Panel off Mode
Recovery time
Setting range
Default
Timer
Mode
1) Timer settings and recovery time (System settings => Timer setting)
This mode can start
This mode cannot start
If Panel Off < Auto Off
This mode can start
This mode cannot start
If Panel Off = Auto Off
This mode can start
This mode can start
If Panel Off > Auto Off
Auto Off Mode
Panel Off Mode
Specified values for timers
Panel off only
Level 1
2) Energy saver level setting (System setting => Administrator Tools => Energy saver level )
Power
Consumption
Warm-up
Operation Mode
Ready Mode
Panel Off Mode
Off/Sleep Mode
Panel Off Timer
10 sec – 240 min
Timer Starts
Auto Off Timer
1 – 240 min
After 240 min
from last job
Plug In
Time
The user can set these timers with User Tools
MFP/ Priport: User Tools > System settings > Timer Setting
Printer
: User Tools > System settings > Energy Saver Timer
Normally, Panel Off timer < Energy Saver timer < Auto Off timer.
But, for example, if Auto Off timer < or = Panel Off timer and Energy Saver timer,
the machine goes immediately to Off mode when the Auto Off timer expires. It
skips the Panel Off and Energy Saver modes.
Example
¾
Panel off: 1 minute, Low power: 15 minutes, Auto Off: 1 minute
¾
The machine goes to Off mode after 1 minute. Panel Off and Low Power
modes are not used.
We recommend that the default settings should be kept.
¾
If the customer requests that these settings should be changed, please
explain that their energy costs could increase, and that they should
consider the effects on the environment of extra energy use.
¾
If it is necessary to change the settings, please try to make sure that the
Auto Off timer is not too long. Try with a shorter setting first, such as 30
minutes, then go to a longer one (such as 60 minutes) if the customer is not
satisfied.
¾
If the timers are all set to the maximum value, the machine will not begin
saving energy until 240 minutes has expired after the last job. This means
that after the customer has finished using the machine for the day, energy
will be consumed that could otherwise be saved.
¾
If you change the settings, the energy consumed can be measured using
SP8941, as explained later in this presentation.
Power consumption during warm-up may be much higher than shown in this
diagram.
Содержание M052
Страница 3: ...SH MF1 Training 3 Slide 3 PRODUCT OUTLINE Introduction No additional notes ...
Страница 12: ...SH MF1 Training 12 Slide 12 Product Outline New Features No additional notes ...
Страница 18: ...SH MF1 Training 18 Slide 18 PRODUCT OUTLINE Specifications This section explains the important specifications ...
Страница 22: ...SH MF1 Training 22 Slide 22 Product Outline Options No additional notes ...
Страница 30: ...SH MF1 Training 30 Slide 30 SMC Sheet The SMC sheet is under the platen cover in the ARDF No additional notes ...
Страница 45: ...SH MF1 Training 45 Slide 45 Transporting the Machine No additional notes ...
Страница 47: ...SH MF1 Training 47 Slide 47 Maintenance No additional notes ...
Страница 86: ...SH MF1 Training 86 Slide 86 ADF Motor Cooling The fan pulls in air to cool the motors Fan No additional notes ...
Страница 87: ...SH MF1 Training 87 Slide 87 Scanner No additional notes ...
Страница 112: ...SH MF1 Training 112 Slide 112 Laser Exposure No additional notes ...
Страница 117: ...SH MF1 Training 117 Slide 117 All In One Cartridge AIO ...
Страница 127: ...SH MF1 Training 127 Slide 127 Fusing No additional notes ...
Страница 135: ...SH MF1 Training 135 Slide 135 Paper Exit No additional notes ...
Страница 167: ...SH MF1 Training 167 Slide 167 One bin Tray M053 only No additional notes ...