T
echnical
B
ulletin
PAGE: 3/4
Model:
Ko-P1
Date:
13-Mar-19
No.:
RM0BY001
Adjusting Head Position in the Direction of Sub Scan (P.244~)
5. Adjust the head position until the value displayed on the operation panel turns ± 10 m. Rotate
the sub scan direction head position adjustment cam [A] to adjust the head position.
For the rotation angle of the cam, refer to the following table and the graph in the step 5, Adjusting
Head Inclination.
Rotation angle (degree)
Moving distance ( m)
10
2.8
20
5.7
30
8.6
40
11.5
50
14.4
60
17.4
70
20.4
80
23.5
90
26.7
100
30
110
33.3
120
36.8
130
40.5
140
44.4
150
48.5
160
53.1
170
58.2
180
64.1
190
71.8
200
90