BIT SWITCHES
21 December, 2001
3-52
G3-2 Switch 0B
SP No. 1-106-012
No
FUNCTION
COMMENTS
0
Protocol requirements: Europe
0:
Disabled
1:
Enabled
1
Protocol requirements: Spain
0:
Disabled
1:
Enabled
2
Protocol requirements:
Germany
0:
Disabled
1:
Enabled
3
Protocol requirements: France
0:
Disabled
1:
Enabled
4
PTT requirements: Germany
0:
Disabled
1:
Enabled
5
PTT requirements: France
0:
Disabled
1:
Enabled
The machine does not automatically reset these bits
for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
6
Not used
Do not change the settings.
7
Not used
Do not change the settings.
G3-2 Switch 0C
SP No. 1-106-013
No
FUNCTION
COMMENTS
0
1
Pulse dialing method
Bit 1 Bit 0
Setting
0
0
Normal(P=N)
0
1
Oslo (P=10 - N)
1
0
Sweden
(N+1)
1
1
Not used
P = Number of pulses sent out, N = Number dialed.
2-7
Not used
Do not change the settings.
G3-2 Switch 0D
- Not used (do not change the settings)
G3-2 Switch 0E
- Not used (do not change the settings)
G3-2 Switch 0F
- Not used (do not change the settings)