10.3 FUSING TEMPERATURE CONTROL
10.3.1 Fusing Circuit Operation
The fusing lamp is powered by AC controller 1 and controlled by the main
board.
AC controller 1 receives direct wall voltage ac power (not stepped down) at
T304 and T306. It also re24 volts at CN301-5. The ac power is
applied to the drive circuit, the fusing lamp (L3), and the triac (TR). The dc
power drives PC301 and RA301.
To turn on the fusing lamp, the main board drops CN107-A15 to LOW. This
activates the photocoupler (PC301) which in turn energizes the drive circuit.
The drive circuit turns on the triac to complete the lamp circuit, thus turning
on the lamp.
RA301 guards against a failure of the +24 volt power supply. When +24 volts
is applied at CN301-5, RA301 is energized and its ac contacts stay open. If
the +24 volts power stops, the ac contacts of RA301 close, stopping the drive
circuit and turning off the fusing lamp (U.S.A. version only).
Overheat Protection
+
+24
+24
Q101
IC107
1K
1.3K
6
5
7
CN107-A25
-5
CN107-A15
CN107-B25
CN301
A.GND
-6
-3
Drive Circuit
RA301
PC301
AC115,220,240
AC Controller 1
T304
T306
TR
G
T309
T310
T308
T307 T305
CN110-12
CN110-11
CN110-9
CN110-10
TH2
TH1
L3
+5
C
P
U
TF1
24
RA
301
_
+5
RA301: U.S.A. version only
31 December 1992
FUSING AND PAPER EXIT
2-43
Содержание FW830
Страница 3: ...SECTION 1 OVERALL MACHINE INFORMATION...
Страница 18: ...A0 E A1 D Lengthwise Switching Back Switching Back 31 December 1992 ORIGINAL AND PAPER PATH 1 15...
Страница 19: ...SECTION 2 DETAILED SECTION DESCRIPTIONS...
Страница 68: ...SECTION 3 INSTALLATION...
Страница 86: ...SECTION 4 SERVICE TABLES...
Страница 140: ...SECTION 5 REPLACEMENT AND ADJUSTMENT...
Страница 209: ...SECTION 6 TROUBLESHOOTING...
Страница 223: ...74 72 73 76 75 79 85 84 83 82 80 81 86 87 88 77 78...
Страница 224: ...90 89...