10.6 ADS (Auto Image Density Sensor) ADJUSTMENT
When:
ADS voltage is not within the adjustment standard.
Purpose:
To maintain correct ADS mode operation.
Adjustment
Standard:
ADS Reference Voltage = 3.0
±
0.1 volts
Perform:
SP #37
How:
Change the ADS reference voltage by VR103.
The voltage reading is displayed on the operation
panel.
1. Clean the white plate and auto image density sensor.
2. Remove the middle right cover.
3. Turn on the main switch.
4. Turn on DPS101-8 on the main board to enter the SP mode.
5. Select SP#37 (See Service Program Mode Access Procedure) and press
the Copy Exit Way key.
6. If the voltage is not within the adjustment standard, adjust it by turning
VR103 on the main board [A].
[A]
COPY QUALITY ADJUSTMENT
31 December 1992
5-62