![Ricoh FW830 Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/ricoh/fw830/fw830_service-manual_1456243184.webp)
7.2
QUENCHING LAMP REPLACEMENT
1. Remove the middle left and middle right covers.
2. Remove the left and right horizontal covers. (See Left and Right
Horizontal Cover Removal.)
3. Remove the cooling fan motor [A] (2 screws and 1 connector).
4. Remove the press roller plate [B] (4 screws).
5. Remove the 4th press rollers [C] (7 sets ....... 2 screws each).
6. Remove the quenching lamp unit [D] (4 screws).
7. Remove both quenching lamps from the quenching lamp bracket (4
screws each).
[C]
[D]
[A]
[B]
QUENCHING
31 December 1992