Service Program Table Contd.
Number
ID Setting (1)
Lead Edge
Erase
Function
21
ID Sensing Interval
0 ...1220 mm (Normal)
1 ...610 mm
22
ID Sensor Grid
Voltage Adjustment
0 ...--460 V
1 ...--380 V
2 ...--400 V
3 ...--420 V
4 ...--440 V
5 ...--480 V
6 ...--500 V
23
Copy Grid Voltage
Adjustment
0 ... 0 V
1 ...+40 V
2 ...+20 V
3 ...--20 V
4 ...--40 V
24
PTL OFF (trailing
edge)
0 ...PTL ON (Factory
.....setting)
1 ...+10 mm
2 ...+5 mm
3 ... 0 mm
4 ...--5 mm
5 ...--10 mm
6 ...--15 mm
7 ...--20 mm
8 ...--25 mm
9 ...--30 mm
26
Fine Registration
Adjustment
(0.25 mm/step)
0 ...0 mm
1 ...--1.0 mm
2 ...--0.75 mm
3 ...--0.5 mm
4 ...--0.25 mm
5 ...+0.25 mm
6 ...+0.5 mm
7 ...+0.75 mm
8 ...+1.0 mm
Lighter Copy
Auto
Image Density
20 mm
15 mm
10 mm
5 mm
Lighter Copy
Auto
Image Density
20 mm
15 mm
10 mm
5 mm
Lighter Copy
Auto
Image Density
20 mm
15 mm
10 mm
5 mm
Lighter Copy
Auto
Image Density
20 mm
15 mm
10 mm
5 mm
Lighter Copy
Auto
Image Density
20 mm
15 mm
10 mm
5 mm
ON
1
2
3
4
5
6
7
8
6 January 1990
4-9
Содержание FW 810
Страница 1: ...SECTION 1 OVERALL MACHINE INFORMATION...
Страница 22: ...SECTION 2 DETAILED SECTION DESCRIPTIONS...
Страница 73: ...SECTION 3 INSTALLATION...
Страница 88: ...SECTION 4 SERVICE TABLES...
Страница 122: ...SECTION 5 REPLACEMENT AND ADJUSTMENT...
Страница 152: ...5 Clean the toner overflow sensor E with a blower brush or equiva lent E 6 January 1990 5 30...