2.3 ADS SENSOR ADJUSTMENT
ADJUSTMENT STANDARD: 3
±
0.1V
1. Open the upper unit
and clean the white
plate.
2. Remove the right
middle cover.
3. Turn on DIP101-8.
NOTE:
Voltage can be veri-
fied by attaching
multimeter leads to
TP104 (ADS OUT)
and TP106 (GND).
4. Close the upper
unit and turn on the
main switch.
5. Press the Lighter
key [A] 6 times to
select ID level 6,
and press the
Lead Edge Erase
key twice [B] to
specify 10 millime-
ters.
6. Press the Copy Exit
Way key [C].
7. Adjust the ADS out-
put to + 3.0
±
0.1
volts by turning
VR103.
8. Turn off the main
switch and turn off
DIP switch 101-8.
[A]
[C]
[B]
6 January 1990
5-5
Содержание FW 810
Страница 1: ...SECTION 1 OVERALL MACHINE INFORMATION...
Страница 22: ...SECTION 2 DETAILED SECTION DESCRIPTIONS...
Страница 73: ...SECTION 3 INSTALLATION...
Страница 88: ...SECTION 4 SERVICE TABLES...
Страница 122: ...SECTION 5 REPLACEMENT AND ADJUSTMENT...
Страница 152: ...5 Clean the toner overflow sensor E with a blower brush or equiva lent E 6 January 1990 5 30...