CODE #29 — LENS HOME POSITION ERROR 2
- Definition -
The lens home position sensor’s output remains HIGH (actuated) for 10
seconds after the unit leaves the home position.
- Possible Causes -
•
Defective lens home position sensor
•
Defective lens drive motor
•
Defective main control board
•
Defective lens drive mechanism
CODE #40 — OPTICS THERMISTOR ERROR
-Definition-
The optics thermistor is open.
- Possible Cause -
•
Defective optics thermistor
•
Defective main control board
•
CN121 on the main control board is not correctly connected.
CODE #42 — HIGH VOLTAGE LEAKAGE
- Definition -
The high voltage supply board detects the leakage and sends the leak
signal to the main control board for more than 1 second.
- Possible Causes -
•
Transfer charge unit
•
High voltage supply board
•
Main control board (CN102-1)
SERVICE CALL CONDITIONS
20 December 1996
7-26
Содержание FT 4015
Страница 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Страница 10: ...5 PAPER PATH 1 2 3 A219V502 wmf 1 By pass Feed 2 Paper Tray Feed 3 Copy Tray PAPER PATH 20 December 1996 1 8...
Страница 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Страница 71: ...SECTION 3 INSTALLATION...
Страница 90: ...SECTION 4 SERVICE TABLES...
Страница 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Страница 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Страница 190: ...SECTION 7 TROUBLESHOOTING...
Страница 212: ...Yes No Change or clean the defective parts Replace the main control board COPY QUALITY 20 December 1996 7 22...
Страница 222: ...SECTION 8 OPTIONS...
Страница 223: ...SECTION 9 APPENDIX TIMING CHART...
Страница 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Страница 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Страница 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...