Installation Requirements 1-2
II
L
00
1.4 Tools
Required
Table 1.2 Tools Required
Item
Name
Usage
1
Cutter
Unpacking
2
Phillips Screw Driver NO.2 shaft
length; approx. 40 and 100mm
Removing and installing the screw for covers
3
Adjustable Open End Wrench
Leveling the bolt
Fixing the leveling the bolts
4
Level Meter
Installation the Container Stacker
1.5 Environmental
Conditions
Table 1.3 Environmental Conditions
Items
Value
Temperature
10 ~32 °C (50 ~ 89.6°F)
Humidity
20 ~80 %RH
(Wet Bulb 26 °C (78.8 °F ) max.)
Altitude
0 to 2,100 m (0 to 7,000 feet) max.
1.6 Input Line Voltage
Table 1.4 Print Engine Input Line Voltage
Input Line Voltage
AC 200V ~ AC 240V
Phase
Single Phase, two wires and grounding wire
Frequency
50/60 Hz ±1Hz
Transient (Static)
±10%
Transient (Dynamic)
–18% / +15% 500ms
Drop out
-100%, 20ms
II
L
01
Содержание DDP 92
Страница 1: ...Installation Manual 2005 Ricoh Printing Systems Ltd March 2007 N904117...
Страница 2: ......
Страница 5: ...BLANK...
Страница 23: ...Unpacking 2 10 II L 00 2 Remove the two Upper Packing Outside Packing 3 Remove the High Capacity Hopper...