114
Ricoh Co. Ltd.
http://www.ricoh.com/
B245-62 / PD-C4
Slide 114
SC Codes
Four levels: A – D (See notes)
Reset ‘Level A’ codes with SP 7807
» Level A codes cannot be reset by only switching the
machine off/on.
There are four levels of service call conditions.
Level A: To prevent damage to the machine, the main machine cannot be
operated until the SC has been reset by a service representative (see the note
below).
¾
Reset: Enter SP mode, and then turn the main power switch off and on.
Level B: If the SC was caused by incorrect sensor detection, the SC can be reset
by turning the main power switch off and on.
¾
Reset: Turn the main power off/on.
Level C: The main machine can be operated as usual, excluding the unit related
to the service call.
¾
Reset: Turn the main power off/on.
Level D: The SC history is updated. The machine can be operated as usual.
¾
No reset needed. The SC will not be displayed. Only the SC history is