T
echnical
B
ulletin
PAGE: 3/5
Reissued: 15-Apr-15
Model:
GR-C1
Date:
27-Nov-14
No.:
RD117050b
Permanent solution
Production line:
- Four ribs were added to the exit cover, in order to prevent the laser unit from
moving.
- A seal was attached to the mainframe, in order to prevent noise generated from
the additional ribs.
#
Old P/N
New P/N
Description
Q’ty
Int
Set
1
D1171311 D1171313 COVER:UPPER
1
X/O
A
2
-
D1171064 SEAL:SIDE PLATE:FRONT
1
-
A
Exit cover:
Seal:
Install ribs
COVER:UPPER
:
D1171313
SEAL:SIDE PLATE:FRONT
:
D1171064