10.1.4 Operation Panel
1. Turn off the main switch and unplug the machine.
2. Open the front cover.
3. Swing out the toner bottle holder assembly.
4. Remove the operation panel [A] (4 screws, 3 connectors).
10.1.5 Right Upper Cover
1. Remove the right upper cover [B] (2 screws).
10.1.6 Front Upper Cover
1. Open the front cover.
2. Remove the toner bottle holder assembly. (See Development Unit
Removal.)
3. Remove the operation panel [A] (6 screws, 3 connectors).
4 Remove the left inner cover. (See Inner Cover Removal.)
5. Remove the front upper cover [C] (2 screws).
[A]
[B]
[C]
A195R530-2.wmf
INNER AND OUTER COVERS
25 April 1997
40