background image

SAFETY PRECAUTIONS

MAINTENANCE

2

• 

Never unscrew any connecting parts while the tank is  

 

still under pressure.

• 

Never disassemble any electrical parts before   

 

disconneting the electrical plug.

• 

Always use caution when adjusting the safety valve.

• 

Never use the compressor when the volatage is too low  

 

or too high.

• 

Never use electrical cable more than 5m long with less  

 

than a 1.5 mm section rated to 16A.

• 

Never disconnect the plug to stop the compressor, turn  

 

the switch to the OFF position.

• 

If the release valve does not work when the motor is  

 

stopped find the cause immediately to prevent damage to  

 

the motor.

• 

Before restarting the motor by pressing the RESET   

 

button check the air compressor for problems and check  

 

the pressure in the air tank to ensure it is under 0.8Mpa.

• 

Disconnect the plug to cut off the power supply and open  

 

the outlet valve and discharge all the air in the air tank  

 

after use. 

1. 

Before any maintenance operation stop the air compressor,  

 

cut off the power supply and discharge all the air in the tank.

2. 

Clean the crank case and renew lubricating oil after the   

 

first10 working hours. Check the oil through the oil level   

 

sightglass after every 20 working hours and replenish if   

 

necessary; you can replenish by inbolting the sump bolt, and  

 

srain off any old oil.

3. 

Have the safety valve and pressure gauge checked by a  

 

certified repair centre every 6 months to ensure they are in  

 

correct working condition.

4. 

Make sure there is no rust on the air tank and the air tank is  

 

not damaged.

5. 

Have the thickness of the air tank checked by a certified  

 

repair centre every year to ensure the tank thinkness is not  

 

less than 2.1mm.

CAUTION

MAINTENANCE PROCEDURE

Sump bolt

11

10

Содержание PAC-96-24

Страница 1: ...RICHMOND OWNERS MANUAL Air Compressor PAC 96 24 PAC 96 50 ...

Страница 2: ...fety and protect you from harm or damage to the product All photographs and drawings in this manual are supplied by Parker Products Ltd to help you with the operation and maintenance of the product The information contained in this manual was accurate at the time of production however Parker Products Ltd may make modifications without noification Contents List 1 Specification 2 Main Components 3 S...

Страница 3: ...2850 rpm Delivery 9 6 CFM Discharge Pressure 115 psi 0 8 MPa Restart Pressure 70 PSI 0 5 MPa Tank Capacity 24L 50L Dimensions 600x290x645 mm 770X330X730 mm Air Outlet Size 1 4 in Pressure switch Pressure Gauge Drain cock Air Tank resevoir Regulating valve Regulating valve Safetly valve Release valve Discharge Pipe Fan Cover Main Compressor 3 2 ...

Страница 4: ...e the compressor in a clean dry and ventilated area 5 Keep voltage within 4 of the rated value 6 Keep the oil level in the red circle of the oil glass sight window You can purchase compressor oil from our website 7 Open the outlet valve set the power switch knob to the ON position and let the compressor run for 10 minutes with no load to ensure the moving parts are lubricated before regular servic...

Страница 5: ...elease valve under the switch This is a necessary condition before restarting or the motor will be damaged The rated pressure can be altered by turning the adjusting screw The outlet pressure of compressed air can be adjusted by the regulating valve Grip the regulating valve knob and turn it clockwise to increase the pressure PRESSURE GUAGES There are two pressure gauges on the compressor 1 The pr...

Страница 6: ...or is vented remove any condensation from inside the tank by inscrewing the bleed nipple THERMAL RESET SWITCH There may be instances when your compressor will overheat If it cuts out this is the safety feature to protect you and your compressor Leave the compressor a good while before you reset it If the compressor turns off again on reset you should not keep running it as it may be damaged and th...

Страница 7: ...o ensure it is under 0 8Mpa Disconnect the plug to cut off the power supply and open the outlet valve and discharge all the air in the air tank after use 1 Before any maintenance operation stop the air compressor cut off the power supply and discharge all the air in the tank 2 Clean the crank case and renew lubricating oil after the first10 working hours Check the oil through the oil level sightgl...

Страница 8: ... moving parts seriously worn Check and retighten Check and clean Replace with thicker paper gasket Repair or replace Pressure insufficient or discharge capacity decreased Motor running too slow Air filter choked up Leakage of safety valve leakage of discharge pipe Sealing gasket damaged Valve plate damaged stuck or carbon build up Piston ring and cylinder worn or damaged Check and remedy Clean or ...

Страница 9: ...tor cover 1 15 hex bolt M8x22 left 1 49 bolt M5x105 4 16 rubber gasket 1 50 fan 1 17 breath pipe 1 51 circlip 1 18 sealed ringφ13x2 5 2 52 bolt ST3 9x19 2 19 crank case cover 1 53 bolt M5x8 2 20 bolt M6x10 6 54 rotor 1 21 oil leveler gasket 1 55 brearing 6204 1 22 oil leveler 1 56 sealing ring 1 23 only way valve 1 57 capacitance 1 24 pressure switch 1 58 washer 8 1 25 pressure gauge 2 59 nut M8 1...

Страница 10: ...www parkerbrand co uk RICHMOND ...