OPERATION AND ADJUSTMENT
OPERATION
The compressor is controlled by a pressure switch. It can be stopped
automatically as the pressure increases to the maximum and restarted
as pressure decreases to the minimum. The rated pressure has been
adjusted during the manufacturing process - alter this pressure with
caution. As soon as the motor is switched off the compressed air inthe
discharge pipe should be released through the release valve under the
switch. This is a necessary condition before restarting, or the motor
will be damaged. The rated pressure can be altered by turning the
adjusting screw.
The outlet pressure of compressed air can be adjusted by the regulating
valve. Grip the regulating valve knob and turn it clockwise to increase
the pressure.
PRESSURE GUAGES
There are two pressure gauges on the compressor.
1.
The pressure gauge on the RIGHT shows the current pressure
in the reservoir tank.
2.
The pressure gauge on the LEFT shows the ‘user set’ outlet
pressure. This can be adjusted using the regulator.
Glass sight window
Regulating valve