GTR211 Installation Manual:
Rev 1
16
Step 8 - Limit Travel Stops:
Included with your gate motor are two limit travel
stops (Part 6a) which must be fitted to the gear
racks on your gate to ensure safe operation.
The limit travel stops are designed to set the
desired opening and closing position of your
gate. These limit travel stops are designed to
come into contact with the spring limit switch.
Please note:
gates can open and close in
different positions due to different weights of
gates, terrains, slopes (uphill or downhill). The
distance the gate will travel after contacting
the spring limit switch may vary.
Test the spring limit travel stops by moving the gate manually until you hear a click, making sure
contact is made with the spring limit switch on the motor.
To Reset:
When setting new limit travel stop positions please ensure that you turn the power off and
then on again. Turning the power off will reset the limit travel stop memory, allowing for new limit travel
stop positions to be recognised by the motor.
Setting the Limit Travel Stops:
Closed Position:
• Position gate 150-200mm back from the
gate end catch closed position. This will
help in making sure you do not slam the
gate into the end stop/catch when setting
the closed position under power.
• Fit limit travel stop onto the top of gear
rack at the point where it meets the
spring limit switch on the motor.
• Tighten locking screws.
Open Position:
• Position gate 150-200mm back from the
gate stopper open position. This will help
in making sure you do not slam the gate
into the end stop/catch when setting the
open position under power.
• Fit limit travel stop onto the top of gear
rack at the point where it meets the
spring limit switch on the motor.
• Tighten locking screws.
Fig 18
Fig 20
Fig 19