GTR061 Installation Manual:
Rev 3
23
Further Settings and Programming:
VR1: Motor Running Time Adjustment
Rotate clockwise to increase, counter-clockwise to decrease. Motor running time can be set to 10 seconds
minimum, and 90 seconds maximum.
The default setting is at maximum.
VR2: Unused
VR3: Stall Force Adjustment
Rotate clockwise to increase, counter-clockwise to decrease.
The default setting is at midway.
When stall force is enabled (DIP switch 7 is at the ON position), the motor will detect obstacles and impacts to
the gate. If this is during opening, the gate will stop, if this is during closing the gate will stop, and then re-open.
When the motor detects any obstruction or impact during opening, the gate will stop and then return. During
closing the gate will simply stop when detecting any obstacle or impact.
Rotate VR3 clockwise to increase the stall force, counter-clockwise to decrease. The factory default setting is
midway, for any dial adjustment required above this check your gate is free rolling with no resistance (capable
of being moved freely by 1 person).
For safety we strongly reccommend that stall force mode is left Enabled (dip switch 7 is at the on
position) do not switch dip switch 7 to the off postion.