RichAuto S & T Co., Ltd
Add: 5th
floor, No.4 building, No 4. Yard, life Rd, life science park, beiqing St., changping district Beijing, China
Tel
:
010-53275118 Fax
:
010-53275110/53275111 Web site
24
According to menu function,RichAuto sytem menu divided into:
MACHINE
SETUP,AUTO PRO SETUP,SYSTEM SETUP,OPERATE FILE,VERSION
VIEW.
Every main menu has some submenus.
4.2 Menu details
4.2.1
Machine Setup
Users can set the parameters about machine hardware under”Machine Setup”. It
is set by machine producer according to device type. If machine hardware parameter
is not changed,this parameter should also not change. If machine users need to
change
,
please consult machine producer.
Machine setup chart
1.
pulse equiv(Pulse Equivalent)
The number of pulses of the system needs to send when machine moves every
1mm.Unit
:
pulse/mm.
1)
stepper driver
MACHINE SETUP
Pulse Equiv
Table Size
Spindle Setup
Home Setup
Accel
Start Spd
Voltage Setup
C.A.D. Thickness
Max Spd Limit
DistTime Limit
Input Confi