TIMEOUT Sets a time limit within which the next ETX,
STX2 or ETX2 must be detected after the first
STX before the logger jumps on to await next
data sample (in seconds)
0 to 255 (integer)
0
RX2 Enables monitoring of the second RS232 input
(Input 2)
Y
N
N
BAUD Sets baud rate for RS232 data input and output
on RS232 input 1 and RS232 output 1
(NB:RS232 Input 2 and Output 2 are fixed at
4800 baud)
115200
57600
38400
19200
9600
4800
2400
1200
300
110
9600
RATE Sets the sample rate/logging interval (in
seconds)
0 to 60 (integer)
0
SINGLEFILE Sets logging to one continuous log file rather
than daily files
Y
N
N
FILE Modifies file name and extension format
ff.nnn
or
ffffffff.nnn
20.CSV
TIMESTAMP Switches data & time stamping on or off
Y
N
Y
LOG_ALL Disables sampling of data via STX and ETX
commands so that all data is logged
Y
N
N
OUTPUT Controls RS232 output of data to RS232 Output
1
I
L
N
N
HANDSHAKE Enables transmission of response string defined
by RESPONSE on receipt of one of STX, ETX,
STX2 or ETX2
STX
ETX
STX2
ETX2
N
N
RESPONSE Defines ASCII character string to be output on
receipt of handshake string, as specified by
HANDSHAKE
“cc…” – a string of
up to 31 ASCII
characters.
“Q”
RAW Controls modification of unprintable characters
(those of value <10) to <SP> characters
Y
N
N
SWITCH Enables logging of status of switches on Digital
I/O terminals
Y
N
N
STARTUP Controls output of file STARTUP.TXT content to
RS232 Output 1
Y
N
N
RX_INV Controls logic inversion of the received data
Y
N
N
RESET Returns logger to default settings
N/A
N/A