Options
©
Rice Lake Weighing Systems
●
All Rights Reserved
59
8. Ensure the rubber gasket is seated properly around the bolts in the SST4 printer enclosure.
Figure 5-26. Press Down Rubber Gasket Around Bolts
9. Set the main plate over the four studs with recesses around the four holes located downward and press down.
NOTE: Ensure that the communications cable main plate is oriented so that the tapered side is facing up. An easy way to
tell if the main plate is oriented correctly is to note that the four holes on the main plate have counter bores which should
Figure 5-27. Incorrect and Correct Orientation of Main Plate
10. Push the entire SST4 enclosure unit back onto the table or other sturdy work surface.
11. Assemble the split seal plates back together with the cable in between (
, left image).
NOTE: Run finger across the split seal plates to ensure there is no dirt or oil on the surface prior to joining the two surfaces
together. Make sure the larger diameter hole side is facing upwards when putting the two pieces together.
Figure 5-28. Assemble The Split Seal Plates Together
Ensure that the
larger side of
the tapered
pocket is facing
upwards when
placing it on the
four studs
Note counter
bore